en Operating the appliance
24
End of programme
The end of the programme O / ‹:‹‹ is
displayed on the floor – provided the
optical display is switched on and is
visible.
The end of the programme is also
indicated by an acoustic signal. This
function can be changed as follows:
1. Open the door.
2. Switch on ON/OFF switch (.
3. Hold down programme button #
and press START button ` until
•:‹.... is indicated on the digital
display.
4. Release both buttons.
The LED for button # flashes and
the digital display h displays the
factory setting •:‹….
5. Press programme button # until
the factory set value ›:‹ƒ is
indicated on the digital display h.
To change the setting,
1. Press programme button 3. Each
time the button is pressed, the set
value increases by one level; when
the value of ›:‹„ has been reached,
the display jumps back to ›:‹‹ (off).
2. Press START button `, the set
value is saved.
3. Close the door.
Note
Depending on the setting for “Automatic
switch off when programme ends or
interior light”, the optical display is no
longer or only briefly visible.
Automatic switch off after end
of programme or interior light*
Automatic switch off / interior light
* depending on model
To save energy, the dishwasher can be
automatically switched off 1 min or 120
min after the programme ends.
The setting can be selected from ˜:‹‹
to ˜:‹ƒ.
1. Open the door.
2. Switch on ON/OFF switch (.
3. Hold down programme button #
and press START button `
until •:‹... is indicated on the digital
display.
4. Release both buttons.
The LED for button # flashes
and the digital display h displays
the factory setting •:‹….
5. Keep pressing programme
button # until the value ˜:‹... is
indicated on the numerical display
h.
˜:‹‹ Appliance does not
switch off automatically.
The interior light 1"
comes on when the door
is opened irrespective of whether
the ON/OFF switch (
is switched on or off. When
the door is closed the light is off. If
the door is open for longer than 60
min., the light switches off
automatically. The interior light 1"
is lit only when the set value ˜:‹‹
is selected.
˜:‹‚ Appliance switches off after 1 min.
˜:‹ƒ Appliance switches off after 120
min.