Sensor control
In automatic mode, a sensor in the extractor hood
detects the intensity of the cooking and roasting
odours. Depending on the sensor setting, the fan
automatically switches to another fan setting.
Default sensitivity setting: †
Lowest sensitivity setting: ‹
Highest sensitivity setting: Š
If the sensor control responds too quickly or too slowly,
it can be changed accordingly:
1. Press and hold the ‘ symbol for approximately four
seconds when the fan is switched on. The setting is
displayed.
2. The sensor control setting can be changed by
touching the + or - symbol.
3. To confirm the entry, press and hold the ‘ symbol
for approximately four seconds.
Fan run-on time
Touch the - symbol until ‚9 appears.
After approximately 10 minutes, the fan switches off
automatically.
AirFresh function
Touch the 3 symbol until the ‚ 3 appears. The
fan runs for approximately five minutes per hour.
Touch the 3 symbol if you want to end the AirFresh
function.
Noise reduction function
The noise reduction function reduces the fan noise.
Switching on
Touch the 4 symbol.
This function is possible at all fan settings except fan
setting ‚. This function also remains active after the fan
is switched off.
Switching off
Touch the 4 symbol.
Lighting
The lighting can be switched on and off independently
of the fan.
Touch the 6 symbol.
Setting the brightness
Press and hold the 6 symbol until the required
brightness is reached.
Saturation display
When the metal grease filters or the activated charcoal
filter are/is saturated, an audible signal sounds for
approximately four seconds after the fan is switched off.
The following symbols also appear on the display: ”ªª
(metal grease filter) or ’ªª (activated charcoal filter).
If you have not yet done so, the metal grease filters
should now be cleaned or the activated charcoal filter
changed.
For instructions on how to clean the metal grease filters,
please refer to the section: Cleaning and maintenance.
The saturation indicator can be reset while it is flashing.
To do this, touch the - symbol.
Switching over the indicator for circulating-air mode
For circulating-air mode, the electronic control must be
switched over accordingly:
■ The extractor hood must be connected and switched
on.
■ Touch and hold the # and ‘ symbols at the same
time, until the ’‹– indicator lights up for the
circulating-air mode "Starter Set". Repeatedly
pressing and holding this button combination
causes the ’–‘ indicator to light up for the
"CleanAir" circulating-air module.
■ Repeatedly pressing and holding this button
combination switches the electronic control back
over to ducted operation (”‚– indicator).
Audible signal
Switching on the audible signal
Touch and hold the # and + symbols at the same time
for approximately three seconds when the fan is
switched on. An audible signal sounds as an
acknowledgement.
Switching off the acoustic signal
Repeat the "Switching on the acoustic signal" process.