12
Installation
Changing over from exhaust-
air to recirculating mode
05. Screw on the mounting hooks with the
angled part facing outwards. Fig. 5.
06. Screw the support screws.
07. Rest the back of the hood on the wall
and let the hoods enter the
corresponding slots.
08. Holding the cross notched screwdriver
in your hand, slowly screw up the 2
horizontal alignment screws, until the
hood is perfectly horizontal above the
cooker hob. Fig. 5 or 6.
09. Insert and fix with the screw-driver the
safety screws.
10. Insert the screws in the holes of the
upper chimney bracket and screw
them in the plugs.
11. Connect the hood to electricity supply.
12. Connect the air outlet pipe.
13. Mount the two parts of the chimney
fixing on the side the upper part with
2 screws at the chimney bracket and
the lower part with 5 screws at the
body of the hood.
Changing the electronic control system
to recirculating mode:
❑
The standard factory setting is for
operation in exhaust-air mode.
❑
To change the mode, the extractor hood
must have been connected up and
should be switched off.
Change over procedure:
1. Switch off the extractor hood and pull
out the mains plug or switch off the
electricity supply at the fuse box.
2. The lighting LED flashes for about ten
seconds. In this time, press the
a button
three times.
You will hear a signal when the electronic
control system is set to recirculating
mode.
Determining the set mode:
1. Switch off the extractor hood and pull
out the mains plug or switch off the
electricity supply at the fuse box.
❑
When the fan follow-on LED
!
flashes, recirculating mode is active.
❑
When the lighting LED
a flashes,
exhaust air mode is active.