12
Installation
Changing over from exhaust-
air to recirculating mode
5. Attach the upper flue to the support
frame with the 2 screws. Fig. 6.
6. Remove the protective film from the top
part of the flue.
ṇ Attention: Do not damage the
sensitive stainless-steel surfaces.
7. Push up the lower part of the flue and
secure to prevent it from falling down.
Fig. 6.
8. DIE 975 A only; place the glass screen
on the hood. Fig. 7.
9. Install the extractor hood in the support
frame and screw into position at the
required height. Fig. 6.
❑ Extractor hood can be aligned via the
elongated holes.
10. Connect the pipe.
11. Connect the power.
12. Very carefully push down the lower part
of the flue.
13. DIE 975 A only – Raise the glass screen
and remove the protective film from the
adhesive strips.
Attach the glass screen and press into
place. Fig. 7.
14. DIE 995 F only – Install 2 glass screens.
Fig. 8.
❑
The electronic control system has been
set up in the factory for the mode
applicable to the extractor hood version
which you have purchased.
❑
If it becomes necessary to change the
mode, the electronic control system
must also be changed over.
Change over procedure:
The extractor hood must have been
connected up and should be switched off.
❑ For hood with round push buttons ...
1. Press for some seconds at the same
time the push buttons Light and Timer,
you will have appearing in the display
the symbol
~
at the side which will be
followed by the 0.
2. Each time you press the Light push
buttons, it is possibile to change the
shown value from 0 (exhaust air) to 1
(recirculation mode) and viceversa.
3. Press the push button 0 to confirm
choise selected in previous point.
❑ For hood with rectangular push
buttons ...
1. Press and hold the 0 button.
2. While the
0 is displayed, press the
button until
C or ~ is displayed. When
this has taken place, release the button.
Changing from exhaust-air to
recirculating mode:
❑
C goes out shortly afterwards.
The electronic control system will then
have been selected to recirculating
mode.
Changing from recirculation to exhaust
air mode:
❑
~ goes out shortly afterwards.
The electronic control system will then
have been selected to exhaust air
mode.