812887
3
Zoom out
Zoom in
Previous page
1/49
Next page
3
3. Touch the tip of the amplifier probe to the insulation of each suspect conductor.
4. Reception of the tone will be loudest on the subject wire.
5. The plug receptacle is provided to be connected to a headset or handset.
Identifying tip and ring (switch to “Off”):
1. Connect the RED test lead to one line and the BLACK lead to the other line.
2. The LED will glow GREEN when you connect the RED test lead to the RING SIDE of the line.
3. The LED will glow “RED” when you connect the RED test lead to the TIP SIDE of the line.
Identifying line condition (switch to “OFF”):
1. Connect the RED test lead to the RING SIDE of the line and the BLACK lead to the TIP.
2. Watch the LED:
a. A bright green LED indicates a clear line
b. No light indicates a busy line
c. A brightly flickering YELLOW light indicates a RINGING line
Verifying lines (switch to “OFF” then “CONT”):
1. Dial the line to be verified.
2. While the line is ringing, connect the RED lead to the RING SIDE of the line and the BLACK
lead to the TIP.
3. In the “Off” position, the indicator light will flicker YELLOW when the test leads are connected to
the subject pair.
4. If you switch the test set to “CONT”, it will terminate the call on the subject line.
Sending tone (switch to “TONE”):
(Caution: Do not connect to an active AC circuit exceeding 24V in this mode)
1. Connect the test leads to the pair, or attach one lead to ground and one lead to either side of the
line.
2. A dual alternating tone, or a single solid tone, can be selected from the switch inside the tone
generator.
3. Probe the suspected wires with the amplifier probe. Reception of the tone will be strongest on
the subject wire. In the case of ready access to bare conductors, a handset or headset may be
used to receive the tone.
Testing continuity (switch to “CONT”):
(Caution: Do not connect to an active AC or DC circuit in this mode)
1. Connect the test leads to the subject pair.
2. Use “CONT” position.
3. A bright GREEN light indicates continuity. The LED will not glow if the line resistance exceeds
10,000 .
Testing continuity using tone (switch to “TONE”):
(Caution: Do not connect to an active AC or DC circuit in this mode)
1. Connect the test leads to the subject pair.
2. Use a handset or headset at the remote end and touch the wire end(s) with the clip lead(s).
3. Reception of the tone is an indication of continuity.
• Modular testing:
1. All of the above tests are available through the modular plug for line 1 only – red and green
wires.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nedis NWTG100YE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nedis NWTG100YE in the language / languages: All languages as an attachment in your email.

The manual is 2.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info