Do not use the product when the cable or plug is damaged.
Make sure that the electrical supply in your area matches a
voltage of 220 – 240 VAC and a frequency of 50 Hz.
Connect to a grounded socket only.
If necessary, use an earthed extension cable of a suitable
diameter.
Fully extend the power cord and make sure the power cord does
not contact the product.
When using an extension cord, use one which is as short as
possible and fully extended.
Do not let the power cable touch hot surfaces.
Do not close a door on the power cable.
Do not pull the power cable to move the product.
Do not put any objects into openings. Do not use with any
opening blocked.
Do not use the product without the air inlet and outlet covers in
place to avoid touching hot and moving parts that may cause
injuries.
Do not drink water from the product. This may cause illness.
Be aware that the refrigerants should be odourless.
The refrigerants should be added by the manufacturer, its service
agent or similar qualied persons.
Do not use the product in temperatures below 0˚C.
Do not expose the product to direct sunlight or rain.
Do not spill any water on the product.
Do not sit on the product.
Unplug the power cable when the product is not in use for a long
time.
Do not unplug the product by pulling on the cable. Always grasp
the plug and pull.
Do not block the air in- and outlets of the product.
Only install, operate and store the product in a room with a oor
area above 4 m2.
Only store the product in a well-ventilated area.
Do not use external timers or remote control systems to switch
the product on or o.
Place the product in an area without any continuous sources of
ignition (for example: open ames, gas or electrical appliances in
operation).
When the product is installed, operated or stored in a
non-ventilated area, make sure the room is designed to prevent
the accumulation of refrigerant leaks resulting in a risk of re or
explosion due to ignition of the refrigerant caused by electric
heaters, stoves, or other sources of ignition.
When defrosting and cleaning the product, do not use any
means other than those recommended by the manufacturing
company.
Do not puncture or heat any part of the refrigerant circuit.
Installing the product
4Keep a minimum of 300 mm of free space around the product.
4Only move the product in the upright position.
1. Place the product on a stable and at surface.
2. Plug the power cable A5 into a power outlet.
Assembling for continuous dehumidication
(optional)
1. Remove the plug from the water hose connection A8.
2. Place the water hose A9 into A8.
3. Connect A9 to a water container or drainage system (not
included).
4Ensure that A9 is hanging down from A8, so that the water
cannot ow back into the product.
Using the control panel
Button Function
Fan speed button BqPress during the dehumidication or
ventilation mode to switch between
the high and low fan speed.
The low fan speed B2 or high fan
speed indicator LED B1 lights up.
Timer button BePress to cancel or set the duration of
dehumidication.
The timer can be set to a maximum
of 24 hours.
Press Br and Bt to set the time.
The duration is shown in hours.
When the timer function is activated,
the time indicator LED B3 lights up.
- button Br
+ button Bt
Press to set the desired humidity level
within a range of 30% to 80%.
Dehumidify mode button
By
Press to choose from four dierent
modes:
Automatic
Dehumidication
Dry laundry
Ventilation
Power on / standby
button Bu
Press to switch the product on or o.
Bq + BePress and hold Bq and Be for 3
seconds to activate or deactivate the
child lock function.
The child lock indicator LED Bw
lights up.
4The product might make some noise when it is used for the rst
time or after a long period when the product was not used. This
is normal and does not aect the safety of the product.
4Keep the doors and windows closed to allow the product to work
more eciently.
4The room temperature might increase during use, because the
product does not have a cooling function.
Operation modes
Automatic Automatically switches on and o to
maintain a humidity level of 55%.
Automatically switches to high fan
speed when the room humidity level
is higher than 70%.
Automatically switches to low fan
speed when the room humidity level
is between 55% and 70%.
Automatically switches to low fan
speed when the room humidity
level is lower than 55%. The
dehumidication function is disabled.
Set humidity level and fan speed are
disabled.
The automatic dehumidication
mode indicator LED B7 lights up.
Dehumidication Switch on the dehumidication and
ventilator of the product.
The humidity level and fan speed can
be set manually.
The dehumidication mode indicator
LED B6 lights up.
Dry laundry To help dry clothing and upholstery
in the room.
Set humidity level and fan speed are
disabled.
The dry laundry mode indicator LED
B8 lights up.
DEHU10WT_MAN_COMP_0522_print.indd 4DEHU10WT_MAN_COMP_0522_print.indd 4 19-5-2022 13:02:0219-5-2022 13:02:02
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nedis DEHU10WT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nedis DEHU10WT in the language / languages: All languages as an attachment in your email.

The manual is 2.67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info