MAINTENANCE
This section describes the simple maintenance procedures you should
follow to replace the lamp and clean the filter.
Replacing the Lamp
After your lamp has been operating for 1500 hours (up to 2000 hours in
Eco mode) or longer, the LAMP indicator in the cabinet will blink red and
the message will appear. Even though the lamp may still be working,
replace it at 1500 (up to 2000 hours in Eco mode) hours to maintain
optimal projector performance.
CAUTION
DO NOT TOUCH THE LAMP immediately after it has been used. It
will be extremely hot. Turn the projector off, wait 60 seconds, and
then unplug the power cable. Allow at least one hour for the lamp
to cool before handling.
DO NOT REMOVE ANY SCREWS except the lamp cover screw
and the lamp case screw. You could receive an electric shock.
The projector will turn off and go into stand by mode after 1600
(up to 2100 hours in Eco mode) hours of service. If this happens,
be sure to replace the lamp. If you continue to use the lamp after
1500 hours (up to 2000 hours in Eco mode) of use, the lamp bulb
may shatter, and pieces of glass may be scattered in the lamp
case. Do not touch them as the pieces of glass may cause injury.
If this happens, contact your NEC dealer for lamp replacement.
To replace the lamp:
NOTE: The replacement lamp comes with a flat-blade screwdriver. Use the screw-
driver to remove the lamp cover and lamp housing.
1. Loosen the lamp cover screw until the screwdriver goes into a free-
wheeling condition. Press firmly and slide the lamp cover off. The lamp
cover screw is not removable.
3. Insert a new lamp housing until the lamp housing is plugged into the
socket.
CAUTION
Do not use a lamp other than the NEC replacement lamp (LT70LP).
Order this from your NEC dealer.
Secure it in place with the screw.
Be sure to tighten the screw.
4. Reattach the lamp cover.
Slide the lamp cover back until it snaps into place.
Tighten the lamp cover screw.
Be sure to tighten the screw.
2. Loosen the screw securing the lamp housing until the screwdriver goes
into a freewheeling condition. The screw is not removable.
Remove the lamp housing by pulling out the handle.
NOTE: There is an interlock on this case to prevent the risk of electrical shock.
Do not attempt to circumvent this interlock.
Catch
Interlock
5. After you install a new lamp, select the menu
[Default]
[Clear
Lamp Hour Meter] to reset the lamp usage hours.
NOTE: When the lamp exceeds 1600 hours (up to 2100 hours in Eco mode) of
service, the projector cannot turn on and the menu is not displayed. If this
happens, press the Help button on the remote control for a minimum of 10
seconds while in standby mode. When the lamp time clock is reset to zero, the
LAMP indicator goes out.
L
AM
STATU
S
POWER
ON/STA
ND
LAMP
MENU
S
O
U
R
C
E
ENTER
STATUS
POWER
ON/STAND BY
S
E
L
E
C
T
1
2
L
A
M
P
M
E
N
U
E
N
S
T
A
TU
S
P
O
W
E
R
O
N
/S
T
A
N
D
B
Y
L
A
M
P
M
E
N
U
SO
E
N
T
E
S
T
A
T
U
S
P
O
W
E
R
O
N
/S
T
A
N
D
B
Y
L
A
M
P
M
E
N
U
S
O
U
R
C
E
E
N
T
E
R
S
T
A
T
U
S
P
O
W
E
R
O
N
/S
T
A
N
D
B
Y
S
E
L
E
C
T
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nec lt 170 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nec lt 170 in the language / languages: English as an attachment in your email.

The manual is 1,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nec lt 170

Nec lt 170 User Manual - German - 45 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info