688838
15
Zoom out
Zoom in
Previous page
1/22
Next page
All the energy you need
www.ndsenergy.it ~ e-mail: commer@ndsenergy.it
EN.2
SUMMARY
1. SYSTEM COMPONENTS 3Lion + 3Link.
2. SAFETY
3. INTRODUCTION
4. INSTALLATION
4.1 3Link INSTALLATION
4.2 MOUNTING SCHEME
4.3 DISPLAY INSTALLATION
5. OPERATION
5.1 CHARGE
5.2 DISCHARGE
6. OPERATION CHECK
7. VERIFIABLE PROBLEMS
8. TECHNICAL CHARACTERISTICS
9. GUARANTEE
1. SYSTEM COMPONENTS 3Lion + 3Link.
Battery LiFePo4 ' 3Lion '
Display ' 3Link '
Display mounting bracket
Advanced BMS ' 3Link '
Assembly screws (n°. 8)
Use and maintenance manuals
Display connection cable
2. SAFETY
This manual serves as a guide for the installation, use and maintenance of
the 3Lion + 3Link system. It is compulsory to carefully read all its parts
for both the installer and the end user.
Keep the device out of the reach of children.
Read this manual carefully and keep it handy, preferably near the 3Lion , for any
future consultation.
The 3Lion must always be installed with the 3Link .
The 3Lion can be installed with a maximum inclination of 90° compared to its
natural positioning (i.e. with the poles facing up).
Do not bump, puncture, disassemble, deform the 3Lion and the 3link . Do not open
the 3Lion .
In the event of electrolyte leakage, do not touch the battery. In case of contact,
immediately flush skin with warm water and seek medical advice immediately.
Be careful when installing, so that the two poles of the 3Lion do not come in contact
with each other. Use isolated equipment and do not place and/or leave metal objects
close to the product.
Always dispose of the battery according to local laws. Do not dispose of other
industrial waste.
Protect the poles of the 3Lion from any contact with electrically conductive objects.
The device must be protected from direct sunlight or direct heat sources to avoid
overheating.
Do not install the appliance in a sealed environment, otherwise it may overheat.
Make sure that there is air circulation in the room where it is installed.
To avoid the risk of electric shock and/or fire, make sure the power supply is in good
condition.
Do not use the appliance with damaged cables and/or of inadequate cross-section.
Do not use the device in an environment with high humidity or direct contact with
splashes of water and/or liquids or in the rain.
Install the device using cables of the appropriate cross-section as recommended in the
section "INSTALLATION INSTRUCTIONS"
Charge completely right after installing the system or after doing any maintenance on
it. When it is fully charged, the display will show 100% on the battery state of charge
(SOC) display. .
The rated voltage of the 3Lion battery is 12V. Do not use the system with devices that
are not compatible with this voltage. The company is not responsible for any damage
caused by incorrect use of the entire system.
The supplied items are designed exclusively for this system and are not compatible with
other devices. The product pictures in this manual are for reference only and for a purely
explanatory purposes; the product you bought might be different. NDS Energy reserves the
right to make changes to the product at any time without prior notice and without any
obligation to apply these changes to the devices previously distributed.
NDS Energy is not responsible for any malfunctions due to improper use of the product,
any installation mistakes or mistakes present in this manual.
3. INTRODUCTION
3Lion is the innovative NDS battery, built with the reliable Lithium Ferro Phosphate
Technology (LiFePO4) , which combined with the integrated BMS and 3Link system
(BMS Manager), delivers the best performance in the services field due to the
advanced energy system.
Lithium technology provides significant advantages over traditional lead batteries
(AGM, GEL, Free Acid). For example, it can withstand high charging currents, with
a very high efficiency (or very low current dissipated during that phase), which
implies a much better charging speed. It does not suffer from the typical sulfation
of lead batteries, it has a very low self-discharge rate (less than 3%/month), which,
combined with a 60% weight reduction and a large number of cycles (over 2500), it
guarantees more autonomy and remarkable savings in various areas.
The 3Lion dialogues only with the 3Link , which becomes the heart of the energy
system. All the positive aspects of the vehicle's system: Engine Battery, 3Lion
battery and all electrical equipment, so as not to strain the electrical system, are
connected to the 3Link which acts as a BMS manager. This allows for a better
charge management while driving by the alternator, achieving maximum current up
to 75A (depending on the alternator), reducing charging times, and thus achieving
greater autonomy during stops. Once the engine is turned off, the 3Lion service
battery is able, via the BMS manager ( 3Link ), to deliver current for all on board
electrical equipment: lights, heating, coffee machines, etc ... The LiFePO4
technology used for the 3Lion , unlike the traditional Li-Ion or LiPO, is extremely
safe and reliable over time due to its special features. The BMS Manager ( 3Link )
dialogues with the touch screen display that shows all available information about
the state of the battery, the charging system and on-board power consumption
systems.
4. INSTALLATION
To properly install the device, follow the instructions below.
4.1 INSTALLATION OF 3 Link
The 3Lion-3Link system offers maximum performance if supported by a suitable
capacity alternator. It is recommended that the alternator be greater than or equal to
120A with an no-load voltage between 13.8V and 14.7V . No-load measurement means
the voltage measured at the terminals of the engine battery, when the engine is on, the
engine battery is charged or partially charged when all the electrical equipment on
the vehicle is off (lights, conditioner, etc.) and when the services battery is
disconnected from the system.
Prepare an area for housing the 3Link box , as close as possible to the 3Lion , and to the
engine battery, but never in the engine compartment or in compartments that are not
protected from atmospheric agents . Remove the two screws in the front (highlighted in red
in the following figure), lift the cover and pull it out to allow convenient access to the
connection points.
Attach the base of the 3Link to a wall or floor of the housing selected for installation; use
the 4 self-tapping screws in the appropriate holes on the bottom of the base (highlighted in
yellow in the following figure).
4.2 MOUNTING SCHEME:
Before installing, make sure the vehicle engine and the battery charger are off. Do not
make junctions on the cables, make direct connections.
Front View: Rear view:
NUMBER FUNCTION
1 M8 screw connector for engine battery positive terminal
2 M8 screw connector for system common positive
3 M8 Screw Connector for
3Lion
battery positive terminal
4 2-way connector for ground connexion
5 2 way connector for AUX connexion
6 Connection with display
The original, electrical system of the motorhome can be represented in a basic manner by a
relay that connects the engine battery (and thus the alternator) to the service battery when
the vehicle has the engine switched on (i.e. the alternator is in operation and signal D+ is
active). Below is a representation:
The installation of the 3Lion + 3Link is very simple, just intercept in the original system
of the vehicle, the cable that goes from the service battery to the control unit or to the
battery combining relay which in the figure " Original system of the camper " is identified
by number 05. Disconnect cable 05 from the service battery positive terminal, and connect
it to pin 2 of the 3Link .
Make other connections, as shown below.
For connecting the cables to pins 1, 2 and 3 of the 3Link, it is strongly recommended that
you use the terminals for M8 screws (DO NOT use the "fork" type) to ensure a perfect and
secure connection between the cable and the contact of the 3link, as in the following
figure.
1
2
33
4
For connexions 01, 02 and 08, it is recommended the use 35mm
2
cross-section cables, if
the length of the connexion is less than or equal to 1 meter. If the length of the connexion
exceeds 1 meter, it is recommended the use of cables with a cross-section of 50mm
2
. It is
also advisable to install a 200A fuse on cables 01 and 08.
Tighten the terminals firmly to screws 1, 2, and 3 of the 3Link , with the supplied nuts
and washers.
Connections 03, 04, 05 and 06 are usually already present within the vehicle. If not present,
it is recommended to use cables with a section greater than or equal to 10mm
2
.
Connection 07 can be done with cable the cross-section of which is between 1mm
2
and
2.5mm
2
.
As soon as the ground cable is connected to the 3Link, the system becomes operational.
Charge completely just after installing the system or after doing any maintenance on
it. When it is fully charged, the display will show 100% on the battery state of
charge (SOC) display.
Close the 3Link cover by threading the two tabs on the back into the appropriate base
seats; tighten the 2 screws supplied into the holes at the front corners of the cover.
4.3 DISPLAY INSTALLATION
Front View: Rear view:
1
2
3
4
NUMBER FUNCTION
1 Touch screen display
2 Hole for passage of communication cable
3 4 Holes for fixing the cover to the wall
4 System to fix the display frame to the cover
1. Remove the display frame.
2. Position the back cover on the wall chosen for installation. Take the point references
where the holes for the fixing screws (diameter 3 mm) and the communication cable
passage hole (minimum diameter 7.2 mm) are to be made.
3. Drill the holes and screw the back cover to the wall using the supplied screws. Be
careful that once tightened, the screws do not protrude beyond the countersinks.
4. Pass the communication cable through the specially-drilled hole and insert it gently
into the connector on the display circuit board.
DO NOT FORCE THE CONNECTOR.
The connector has an
obligatory direction that must be
followed.
A) Slide the display frame upwards
with respect to the back cover
B) Lift the lower part
of the display
frame
C) Slide the display frame
downwards with respect to the
cover and release it.
5. Attach the display to the back cover:
The 3Link touch screen allows you to interact with the device by easily selecting various
functions.
To properly use the touch screen, follow the instructions below:
Do not exert too much pressure on the surface of the display with your fingers and
do not use sharp objects. Doing so may damage the device or cause it to
malfunction.
Do not put the display in contact with other electrical devices.
Electrostatic discharges can cause malfunction.
Do not put the surface of the display in contact with water. The touch screen may
not work properly in the presence of moisture or if exposed to water and other
liquids.
For best performance, touch the touch screen with your fingertip.
You can use plastic stylus pens for a more accurate touch on the display, but it
is important that they do not have a sharp tip which can damage the surface.
5. OPERATION
The 3Lion + 3Link system allows for the automatic management and display of the
battery status. By means of the display, you can interact with the system and show all the
information such as voltage, current (charging with positive "+" sign, and discharging with
negative sign "-"), and state of charge. The state of charge (SOC) is indicated with coloured
lines ranging from red, indicating that the battery is low, to green, indicating that the
battery is charged.
The advanced 3Link BMS, when it becomes aware that the alternator is operating, it
activates the battery charge intelligently, obtaining maximum current up to 75A (depending
on the alternator characteristics), resulting in a reduction of charging times, and therefore,
greater autonomy during stops. All without overloading the cell system, which is actually
5.1 CHARGE
It is recommended to use LiFePo4 lithium battery chargers. However, you can use a mains
battery charger for AGM/GEL batteries, checking that the maximum voltage supplied by it
does not exceed 14.5V. The charger must NOT perform any desulfation action. The use of
battery chargers for flooded lead acid batteries , although they can completely charge 3lion
batteries, they can reduce their life. If you have a configurable charger, set the CC/CV
(constant current/constant voltage) option, by setting the current value equal to or less than
0.5C, or 50A for the 3L-100, 3L-100B, 3L-100-P models, and 75A for the 3L-150-P model,
and the end--of-charge voltage value to 14.4V.
When the battery is fully charged (the display shows 100%), it is recommended that you
disconnect or turn off the charger. In the case of alternator charge, this is automatically
managed by the 3Link. In fact, 3lion batteries do not need maintenance like lead-acid
batteries.
.52 DISCHARGE
Only for models: 3L-100, 3L-100B
Do not connect equipment with power consumption greater than 100A . However,
this limit may be exceeded, provided that the following limits are met:
Discharge at constant current of 100A: 55minutes maximum *;
Discharge at constant current of 120A: 30 minutes maximum*;
Discharge at constant current of 130A: 15 minutes maximum*;
Discharge at constant current of 150A: 10 minutes maximum*;
Discharge at constant current of 175A: 1 minute maximum*;
Discharge at constant current of 200A: 10 seconds maximum*;
Only for models: 3L-100-P, 3L-150-P
Do not connect equipment with power consumption greater than 150A . However,
this limit may be exceeded, provided that the following limits are met:
Discharge at constant current of 120A: 50 minutes maximum*;
Discharge at constant current of 140A: 20 minutes maximum*;
Discharge at constant current of 160A: 15 minutes maximum*;
Discharge at constant current of 180A: 2 minutes maximum*;
Discharge at constant current of 200A: 20 seconds maximum*;
* Measurements performed at an ambient temperature of 20 °C, and starting temperature of
the lithium battery of 20 °C.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for NDS 3Lion at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of NDS 3Lion in the language / languages: English as an attachment in your email.

The manual is 2,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info