512547
14
Zoom out
Zoom in
Previous page
1/17
Next page
SPEED 3100 log Installation and Operation Manual
NAVMAN
14
Physical
Case size 111 mm (4.4") square.
LCD display 82 mm (3.2") wide, 61 mm (2.4")
high; twisted nematic.
LCD digits 38 mm (1.4") high.
Four operator keys, laser etched.
Backlighting for display and keys, amber, four
levels and off.
Operating temperature 0 to 50°C (32 to 122°F)
Transducer cable length 8 or 9 metres (26.25 ft
or 29.5 ft), depending on transducer.
Power Cable length 1m (3.25 ft).
Electrical
Power supply 10.5 to 16.5 V DC, 30 mA without
backlighting, 100 mA with full backlighting and
transducer.
External beeper or light output, switched to
ground, 30 V DC and 250 mA maximum.
Speed
Displays current speed, average speed,
maximum speed, trim speed.
Range 0 to 50 knots (0 to 58 mph, 0 to 93 km/h).
Display resolution either 0.0 to 19.9, 20 up or
0.00 to 19.99, 20.0 to 29.9, 30 up.
Trim speed displays ± .00 to .99, 1.0 to 9.9,
10 up.
Adjustable damping for speed and trim speed;
values of 1, 2, 3, 4 & 5 average readings over a
time period of 6, 12, 18, 24 & 30 seconds
respectively.
Log
Displays trip log and total log.
Range 0 to 1999 km, miles or nautical miles.
Displays 0.00 to 19.99, 20.0 to 199.9, 200 up.
Appendix A - Specifications
Temperature
Range 0 to 37.7°C (32 to 99.9°F); typical
accuracy < 2°C (32.5°F).
Resolution 0.1 degree.
Countdown timer
Can be set to between 1 and 10 minutes, in
increments of 1 minute.
Counts down in minutes and seconds.
Calibration
Speed and temperature can be calibrated.
Interfaces
NavBus connection to other NAVMAN
instruments.
NMEA 0183 outputs: MTW, PTTKV, VHW,
VLW; input RMC.
Standards compliance
EMC compliance
USA (FCC): Part 15 Class B.
Europe (CE): EN50081-1, EN50082-1
New Zealand and Australia (C Tick):
AS-NZS 3548.
Environment: IP66 from front when correctly
mounted.
Power/data cable wires
Wire Signal
Red Power positive, 12 V DC, 100 mA
maximum
Black Power negative, NMEA common
Green External beeper or light out, switched to
ground, 30 V DC and 250 mA max.
Orange NavBus +
Blue NavBus -
White NMEA out
Yellow NMEA in
9-3 Resetting to factory defaults
All settings may be reset to the manufacturers default
settings (see right).
To reset to factory defaults:
1 Turn the power off.
2 Hold down + while you turn the power on
and continue to hold the keys down for at least
5 seconds.
Speed units ............................................ Knots
Temperature units ....................................... °C
Speed resolution ........................................ 0.0
Speed damping ............................................. 2
Countdown timer start time ................. 10 min
Distance logs ................................................. 0
SIMULATE mode ........................................ Off
Backlight level ............................................... 0
Backlight group ............................................. 1
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Navman Speed 3100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Navman Speed 3100 in the language / languages: English as an attachment in your email.

The manual is 0,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Navman Speed 3100

Navman Speed 3100 User Manual - German - 16 pages

Navman Speed 3100 User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info