Diesel fuel flow sensor kit Installation and Operation Manual
NAVMAN
Once the flow sensors and tachometer pickup
have been installed, install the cables.
When installing a cable:
Keep the cable away from sources of
electrical signals or electrical noise.
Route the cable neatly and out of harms
way.
Do not crush, pinch or strain the cable.
Secure the cable with cable ties or
insulated electrical staples at regular
intervals; run the cable in cable ducting;
or restrain it in some other way.
Ensure no connectors or exposed
terminals are in the bilge.
7-7-1 Link and tachometer
cables
Link cable
The link cable to link the supply sensor to
the return sensor is 2 m (6 ft) long and has
connectors with brown collars:
1 Plug one end into the connector on the
supply sensor with a brown nut. Turn the
collar to lock the connection.
2 Route the cable securely and out of
harms way to the return sensor. If
required, fit an extension cable.
3 Plug the end into the connector on the
return sensor with a brown nut. Turn the
collar to lock the connection.
Tachometer cable
The cable from the tachometer to the return
sensor is 4 m (13 ft) long and has a connector
with a yellow collar:
1 Route the cable securely and out of harms
way from the tachometer to the return
sensor. Secure the cable well so it will not
get caught up in any moving machinery,
or get melted by hot engine surfaces. If
required, fit an extension cable.
2 Plug the end into the connector on the
return sensor with a yellow nut. Turn the
collar to lock the connection.
7-7-2 Connecting to a DIESEL
3200
The sensor cable from the supply sensor up to
the DIESEL 3200 display is 20 metres long. It
has a connector with a white collar on one end
and bared tinned wires on the other:
1 Plug the sensor cable connector into
the connector on the supply sensor with
a white nut. Turn the collar to lock the
connection.
2 Route the sensor cable securely and out
of harms way up to the display unit. If
necessary, fit an extension cable.
3 Connect four wires at the end of the
sensor cable to four of the wires of the
DIESEL 3200 power/data cable, matching
the colours (see below). Use a Navbus
junction box or any simple wire to wire
connector system to join the wires.
4 Install the DIESEL 3200 - follow the
instructions in the DIESEL 3200
Installation and Operation Manual.
Connect the four sensor cable wires
to the DIESEL 3200 power/data cable,
matching the wire colours.
In a twin engine boat, wire the second
sensor cable in parallel with the first,
matching the wire colours.
7-7 Installing the cables
Red
Orange
Black
Blue
One or two sensor cables,
wire in parallel, match colours
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Navman Diesel Fuel Flow Sensors at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Navman Diesel Fuel Flow Sensors in the language / languages: English as an attachment in your email.

The manual is 0,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Navman Diesel Fuel Flow Sensors

Navman Diesel Fuel Flow Sensors User Manual - German - 34 pages

Navman Diesel Fuel Flow Sensors User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info