637932
5
Zoom out
Zoom in
Previous page
1/40
Next page
5
www.napoleongrills.com
EN
Built In Natural Gas Hook-Up: The piping up to the gas grill is the responsibility of the installer and piping
should be located as shown in the built-in instrucons. Do not use hose to connect the unit. It must be
connected with rigid pipe, copper tube or an approved exible metal connector. The installaon must
comply with CAN B149.1 Natural Gas and Propane Installaon Code in Canada, or to the Naonal Fuel
Gas Code, ANSI Z223.1 in the United States. The minimum recommended piping size is NPS 1/2” for
rigid pipe, and 5/8” OD for copper tubing (based on a 20  run). Longer runs may require larger sizes
to conform with local codes or to conform with CAN B149.1. Natural Gas Installaon Code in Canada or
to the Naonal Fuel Gas Code, ANSI Z223.1 in the United States. A exible metal connector is included
to simplify the installaon of the unit. Connect this connector to the 3/8” are ng on the end of the
manifold. Connect the other end of the connector to the gas piping. Ensure that the connector does not
pass through a wall, oor, ceiling or paron, and is protected from damage. For the BISZ300, the gas
supply must be connected to the 3/8” are elbow ng located under the right hand side of the control
panel. For the BISB245, the gas supply must be connected to the 3/8” are ng located on the inlet side
of the included regulator. The included regulator must be used with the appliance.
IMPORTANT! Built in units are supplied with a drip pan which holds only a minimal amount of
grease. To prevent grease res, the pan must be cleaned aer each use.
Leak Tesng Instrucons
WARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING! Never use an open ame to check for gas leaks. Be certain no sparks or open ames
are in the area while you check for leaks. Sparks or open ames will result in a re or explosion,
damage to property, serious bodily injury, or death.
Leak tesng: This must be done before inial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak
Tesng Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Soluons department and have the grill inspected by a cered
gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill
inspected by a cered gas installer or dealer. Do not use the grill unl the leak has
been corrected.
STOP
CYLINDER SIZE OPENING A AREA OPENING B AREA
20 lb (9.1 kg)
20 in
2
(130 cm
2
) 10 in
2
(65 cm
2
)
30 lb (13.6 kg)
30 in
2
(195 cm
2
) 15 in
2
(100 cm
2
)
5” (127 mm)
MAXIMUM
1” (25.4 mm)
MAXIMUM
OPENING
A
OPENING
B
2” (51 mm)
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
NON LOCKING DOOR
34” (864 mm)
RECOMMENDED
5” (127 mm)
MAXIMUM
Propane Enclosure
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Napoleon BISB 245 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Napoleon BISB 245 in the language / languages: English, French as an attachment in your email.

The manual is 4,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info