07
iVECTOR Heater/Cooler
8.0 Water Connection
Before making the pipework connections refer to Section 3 for advice on System Design.
Note: For ease of installation the pipe connections are included with MYSON’S valve kit (see Section 15).
Connect the unit to the flow and return pipes, pipework can be
routed from the floor or through the wall at the back of the unit.
(See options below). Connections are G3/4".
Connection directly onto the heat exchanger should be made
using straight connectors so that the pipework can more easily
be routed inside the unit.
For heating only applications the condensate collector mounted
on the chassis below the heat exchanger connections is not
needed and can be removed by unscrewing the two bracket
fixing screws. Removal of this component will aid pipework
fitting when the pipes are routed up from the floor.
For applications involving cooling, the pipework must be routed
to avoid the condensate collector. Connection to the heat
exchanger should be made using straight connectors so that the
pipework can more easily be routed past the condensate
collector.
Pipe Routing Options
2-pipe connection
(The same options are possible for 4-pipe connection)
Note 1: The flow pipe should be connected to the bottom
connection of the heat exchanger.
Note 2: Isolating valves are not supplied with this unit, but
should be fitted in case of future service requirements.
The type and size of valves and their location should be suitable
for the application. Valves should be selected in accordance with
system temperature and pressure requirements whilst taking into
account pressure drop characteristics.
Note 3: External pipework carrying chilled water must be
insulated. Use a suitable sealant as necessary to ensure that
condensate does not spill or leak. Once connection to the
system flow and return pipes is made, any exposed internal
pipework and isolating valves must also be insulated.
83-108mm* MAX
*Dimension from chassis side to pipe centre.
7.0
8.0
iVECTOR HEATER/COOLER
INSTALLATION, OPERATING, MAINTENANCE & AFTER SALES MANUAL
SS
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Myson iV160 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Myson iV160 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Myson iV160

Myson iV160 Quick start guide - English - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info