677936
3
Zoom out
Zoom in
Previous page
1/48
Next page
4 hours
CAUTION: NEVER connect a laser printer or scanner to the UPS unit. This may
cause the damage of the unit.
Attention hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous
voltage still may be accessible through supply from battery. The battery supply should be therefore
disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service
work inside the UPS is necessary.
CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries
and the required precautions. Keep unauthorized personnel away from batteries.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell battery.
CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery
or batteries. Released electrolyte is harmful to the skin and eyes.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! A battery can present a risk of electric shock and high short circuit current. The following precaution
should be observed before replacing batteries:
1) Remove watches, rings, or other metal objects.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminal.
Before installation, please make sure nothing inside of package is damaged. To protect your equipment
from power failure, be sure that power switch must be kept in the “ON” position. Following below steps to
install your UPS unit.
Placement & Storage Conditions
Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Please place the
UPS away from other units at least 20 cm to avoid interference. Do NOT operate the UPS where the
temperature and humidity is outside the specific limits. (Please check the specs for the limitations.)
Connect to Utility and Charging
Plug in the AC input cord to the wall outlet. For the best results, suggest to charge the battery at least 4 hours
before initial use. The unit charges its battery while connecting to the utility.
Connect the Loads
Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the power switch of UPS
unit, then devices connected to the UPS will be protected by UPS unit.
Connect Modem/Phone/Network for Surge Protection (Only for the model with RJ-11/RJ45)
Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of the UPS unit. Connect
from “OUT” outlet to the computer with another phone line cable.
Connect Com. Port and Install Software (only for the model with RS-232/USB port)
To enable remote UPS shutdown/start-up and status monitoring, connect the communication cable from the
USB/RS-232 port and the other to the communication port of your PC. With the monitoring software installed,
you can schedule UPS shutdown/start-up and monitor the UPS status.
Turn On/Off the Unit
Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again the power switch.
MODEL
400
600
800
CAPACITY
400VA/240W
600VA/360W
800VA/480W
Input Voltage
220/230/240VAC
Input Voltage Range
162-290 VAC
Output Voltage Regulation
± 10 % (Bat. mode)
Frequency Range (Batt. Mode)
50Hz +/-1 Hz
Transfer Time
Typical 2-6 ms
Waveform
Simulated Sine Wave
Battery Type & No
12V/4.5Ahx1
12V/7Ahx1
12V/9Ahx1
Charging Time
4-6 hours recover to 90% capacity
Dimension (DxWxH) mm
LED: 279 x 101 x 142 / LCD: 300 x 101 x 142
Net Weight (kgs)
LED
3.55
4.2
4.9
LCD
3.7
4.4
5.0
Humidity
0-90% RH @ 0-40°C non-condensing)
Noise Level
Less than 40dB
MODEL
1000
1500
2000
CAPACITY
1KVA/600W
1.5KVA/900W
2KVA/1200W
Input Voltage
220/230/240VAC
Input Voltage Range
162-290 VAC
Output Voltage Regulation
± 10 % (Bat. mode)
Frequency Range (Batt. Mode)
50Hz +/-1 Hz
Transfer Time
Typical 2-6 ms
Waveform
Simulated Sine Wave
Battery Type & No
12V/7Ah x 2
12V/9Ah x 2
12V/9Ah x 2
Charging Time
4-6 hours recover to 90% capacity
Dimension (DxWxH)
320 x 130 x 182
Net Weight (kgs)
8.2
10.4
11
Humidity
0-90% RH @ 0-40°C (non-condensing)
Noise Level
Less than 40dB
Problem
Possible Cause
Solutions
No LED display on the front
panel.
Low battery.
Charge the UPS at least 6 hours.
Battery fault.
Replace the battery with the same type of
battery.
The UPS is not turned on.
Press the power switch again to turn on
the UPS.
Alarm continuously
sounds when the
mains is normal.
The UPS is overload.
Remove some loads first. Before
reconnecting equipment, please verify
that the load matches the UPS capability
specified in the specs.
When power fails, back-up time
is shorten.
The UPS is overload.
Remove some critical load.
Battery voltage is too low.
Charge the UPS at least 6 hours.
Battery defect. It might
be due to high
temperature operation
environment, or improper
operation to battery.
Replace the battery with the same type of
battery.
The mains is normal but the
unit is on battery mode.
Power cord is loose.
Reconnect the power cord properly.
User Manual
EN
EN
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mustek PowerMust 800 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mustek PowerMust 800 in the language / languages: English, German, French, Italian, Polish, Portuguese, Finnish as an attachment in your email.

The manual is 2,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info