Calibrating the Scanner
When scanned image’s colors appear not to match the colors of the
original, or colors appear in the white areas of the images, calibration
helps to correct these problems by compensating variations in the
scanner components that happens over time.
1.
Turn on the power of the scanner.
2.
Press Start > All Programs > iDocScan
D20 > Calibration Utility to open the
calibration screen.
3.
Remove the plastic foil on both
sides of the Calibration Sheet.
4.
Insert the Calibration Sheet into the
ADF tray with the arrow mark facing
up and forward.
5.
Press “Calibrate” to start calibrating.
The Calibration Sheet will be
gradually fed through the ADF.
A progress bar will appear
indicating the calibration process.
Mechanical sounds produced during
the calibrating process are normal.
6.
Press “Close” after “the calibration is
done” window appears.
Replacing the Separation Pad
The Separation Pad in the ADF part is a consumable item. After approx.
30000 times of scanning, it may become worn. Replace the Separation
Pad when it is worn, damage or misfeeding continues to occur after
cleaning. A spare Separation Pad is included with the scanner, please
replace it as following steps.
1.
Turn off the power, and then lift open the ADF Cover.
2.
Press both springs on each side of the Separation Pad, pull the pad
backwards and lift it off the ADF Cover.
MAINTENANCE
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mustek iDocScan D20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mustek iDocScan D20 in the language / languages: English as an attachment in your email.

The manual is 1,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info