30242
13
Zoom out
Zoom in
Previous page
1/16
Next page
PROFI mc 4000PROFI mc 4000
Version 2.0
13
You will find the switch for DIRECT THROTTLE un-
der the options for the COLLECTIVE PITCH control.
CONTR D :COL.PITCHÄ
;DIR.THROT
,S06'*
In the base types the switch S06 is assigned here as
standard. If you assign ON instead of a switch, then
throttle is always controlled via the transmitter control
IDLE-UP - except during AUTO-ROTATION.
'' TIP:
For electric-powered helicopters DIRECT THROTTLE
ON is the most suitable mode of operation.
If you use THROTTLE as the transmitter control and
servo, then the link with AUTO-ROTATION is not
automatically present, and must be programmed
separately.
This is how IDLE-UP works:
The IDLE-UP transmitter control limits the travel of
the throttle servo. The COLLECTIVE PITCH stick af-
fects the throttle curve only if the associated value is
below the limit set by idle-up. The following diagram
shows the connection.
When the idle-up slider is in the position shown, the
shaded area in the diagram is blocked for the throttle
servo.
Where the throttle curve runs into the shaded area,
throttle is limited to the value set by the IDLE-UP con-
trol. In our diagram that is about 60%.
In the middle range the throttle curve dips below the
limit. Here the throttle servo will react to movements
of the COLLECTIVE PITCH stick.
If IDLE-UP is pulled right back (e.g. for starting the
motor) the throttle servo no longer responds to the
COLLECTIVE PITCH stick.
In this example throttle is set to about 20%.
In this diagram you can also see that throttle can be
reduced down to 0% using the IDLE-UP control, i.e.
you could stop the motor in this way. In version 1.0 of
the software this was the only possibility. The ability
to define a value for idle is only possible in Version
2.0 and later.
This is how to adjust the idle speed:
Adjust the IDLE-UP transmitter control so that the mo-
tor idles smoothly and stably at the rear end-point.
We will assume that the throttle servo is at -70%
when this is the case.
The next diagram is intended to show how the size of
the carburettor opening varies in relation to the values
for the throttle servo, the IDLE-UP control and the
THROTTLE CURVE.
The THROTTLE CURVE is set to a range of values
between 0% and 100%.
IDLE-UP works between -100% and +100%.
The DYNAMIC THROTTLE servo also works over
the range -100% to +100%, which corresponds to the
full angular travel of the servo from one end-point to
the other.
The three „holes“ on the right-hand side of the dia-
gram show how the carburettor opening corresponds
to these settings.
For example, if you want to set the idle value to 15%
(with reference to the throttle curve), this corresponds
to a value of -70% at the servo.
The same applies if you want to limit the travel of
the transmitter control for idle-up.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Multiplex PROFIcar4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Multiplex PROFIcar4000 in the language / languages: English as an attachment in your email.

The manual is 0,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info