628913
14
Zoom out
Zoom in
Previous page
1/48
Next page
Table of contents
Power Peak® A4 EQ-LCD
6
NiMH charging mode
When charging NiMH batteries, the charger is
switched off using the Delta Peak Method.
Battery status Status LED
1 No charging
LED and battery type flash
green at 0.5 sec intervals
2 Charging started LED constantly lights green
3 Battery charged
Beeper sounds for 15 sec
LED lights orange
8. Equalizing Without Charging
1. Use the voltage sensor lead to connect a
lithium battery to the charger via the voltage
sensor connection.
2. Ensure correct polarity and position when
connecting. The black wire of the sensor lead
must be aligned with the arrow mark on the
charger casing.
3. Ensuring correct polarity, now connect the
main power cables of the battery to the con-
nection at the charger (red = +/black = -).
4. Briefly press the Start button.
5. The battery voltage is shown in the display
during the charging process.
6. Briefly press the Start button again to stop the
equalizing process.
The equalizer LEDs indicate the status of the
connected cells.
Constantly flashing or lit LEDs indicate that the
cells are being balanced.
The LEDs only flashing sporadically or off indi-
cate that the battery is balanced and is ready for
use.
Battery status Status LED
1 Equalizing phase
LED flashes orange
at 0.5 sec intervals
2 End of equalizing
LED flashes orange with
number of cells, beeper
sounds for 15 sec
9. Fault Signalling
A fault is indicated by the status LED flashing
in the corresponding LED flash sequence, (----)
flashing in the LC display and the beeper sound-
ing at 0.5 second intervals.
After eliminating the cause of fault, the fault code
memory is reset by pressing the Start button.
Cause of fault
LED
flash sequence
1
Input voltage is lower than
11 or higher than 15 Volt
1
2
Battery connected with
reversed polarity
2
3
Main power supply cable dis-
connected during charging
3
4
Sensor lead disconnected
during charging
5
5 Fault in power circuit 6
10. Specification Charger
Input:
11...15 V DC /
110-230 V AC
Number of cells:
1...4 LiPo cells
4 ... 8 NiMH cells
Charging current: 0.3 ... 3 A
Charging power: max. 30 W
Charge termination: CC-CV/Delta Peak
Dimensions: 120 x 65 x 24 mm
Protective functions
- Input side:
- Output side:
Polarity reversal protection
Polarity reversal and
short-circuit protection
11. Specification – Power Supply Unit
(No.8560)
Input: 110-230 V AC/50 Hz
Charge current max. 4 A
Output: 12 V DC
Dimensions: 111 x 47 x 33 mm
Protective functions
- Output side:
Polarity reversal
protection
# 30 8560
14
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Multiplex Power Peak A4 EQ-LCD - 30 8560 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Multiplex Power Peak A4 EQ-LCD - 30 8560 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 2,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info