683941
4
Zoom out
Zoom in
Previous page
1/46
Next page
TECHNICAL MANUAL TS 3x.10 KNX ENGLISH
4
Overview parameters
Parameters
Subcategory parameters
Description
Global
settings
Global settings
Send „in operation “(incl. cycle time), request status (active/inactive, request with…), send delay after bus voltage recovers in seconds.
Temperature
Temperature sensor
Settings temperature sensor: Enable disable, send measured values, offset adjustment, notification of sensor error, external value
enabled/disabled.
Temperature alarms
Settings frost- and/or heat alarms: Enable disable, send measured values.
Temperature control
Settings temperature control: Type (inactive, heating, cooling, heating & cooling), different control values (extra cooling level & guide).
Inputs
General
E1…E5 general
E1…E5 parameters
Limitation of number and interval of telegrams to be send
Labeling of inputs, selection of function as analogue-/binary-/temperature input (functions depending on input)
Binary input: switching/alarm, dimming, blinds/shutters, value, scene, switching sequences, multiple operation, pulse counter
Analogue input (E1 only): Voltage, upper/lower measuring limits, output value, threshhold, limits changeable via bus
Temperature sensor input (E4/5 only): Function temperature / temperature limiter floor heater, sensor type, offset, error compensation,
threshold 1, threshold 2
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Muller TS 31.10 knx at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Muller TS 31.10 knx in the language / languages: English as an attachment in your email.

The manual is 1,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Muller TS 31.10 knx

Muller TS 31.10 knx User Manual - English - 2 pages

Muller TS 31.10 knx Installation Guide - German - 46 pages

Muller TS 31.10 knx User Manual - German - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info