683943
14
Zoom out
Zoom in
Previous page
1/55
Next page
TECHNICAL MANUAL GS 3x.10 KNX ENGLISH
14
Number Name Object function C R
W T U Objekt size Data type
141
E4 Output value
output
C
-
-
T
-
2 Bytes
float value, Temperature (°C)
142 E4 dimming output C - - T - 4 Bit 3-Bit controlled, Dimmer step
142 E4 STOP/slat adjustment output C - - T - 1 Bit step
142 E4 switch (Event 1) output C - - T - 1 Bit switching
142 E4 priority (Event 1) output C - - T - 2 Bit priority switching
142 E4 1-Byte value (-128...127) (Event 1) output C - - T - 1 Byte 8-Bit unsigned value, counter pulses (0...255)
142 E4 1-Byte value (0...255) (Event 1) output C - - T - 1 Byte counter pulses (0...255)
142 E4 Scene (Event 1) output C - - T - 1 Byte scene control
142 E4 2-Byte value (-32.768...32.767) (Event 1) output C - - T - 2 Bytes 2-Byte signed value, pulses difference
142 E4 2-Byte value (0...65.535) (Event 1) output C - - T - 2 Bytes 2-Byte unsigned value, pulse
142 E4 4-Byte value (-2.147.483.648...2.147.483.647) (Event 1) output C - - T - 4 Bytes 4-Byte signed value, counter pulses
142 E4 4-Byte value (0...4.294.967.295) (Event 1) output C - - T - 4 Bytes 4-Byte unsigned value, counter pulses
142 E4 2-Byte Floating point (Event 1) output C - - T - 2 Bytes float value, Temperature (°C)
142 E4 switching level 2 output C - - T - 1 Bit switching
142 E4 switching 2 actuation output C - - T - 1 Bit switching
142 E4 ZZ: Counter reading 1-Byte-value output C - - T - 1 Byte 8-Bit unsigned value, counter pulses (0...255)
142 E4 ZZ: Counter reading 1-Byte-value output C - - T - 1 Byte counter pulses (0...255)
142 E4 ZZ: Counter reading 2-Byte-value output C - - T - 2 Bytes 2-Byte signed value, pulses difference
142 E4 ZZ: Counter reading 2-Byte-value output C - - T - 2 Bytes 2-Byte unsigned value, pulse
142 E4 ZZ: Counter reading 4-Byte-value output C - - T - 4 Bytes 4-Byte signed value, counter pulses
142
E4 Output value request
input
C
-
W
-
-
1 Bit
switching
142 E4 Output value request input C - W - - 1 Bit switching
143 E4 Start event 0/1 input C - W - - 1 Bit switching
143
E4 End position top
input
C
-
W
-
-
1 Bit
Boolean
143 E4 Scene storage display output C - - T - 1 Bit enable
143 E4 switching level 3 output C - - T - 1 Bit switching
143 E4 switching 3 actuation output C - - T - 1 Bit switching
143 E4 HZ: Counter reading request input C - W - - 1 Bit switching
143 E4 Measured value out of range output C - - T - 1 Bit switching
143 E4 Measured value out of range output C - - T - 1 Bit switching
144 E4 End position bottom input C - W - - 1 Bit Boolean
144 E4 switching level 4 output C - - T - 1 Bit switching
144 E4 switching 4 actuation output C - - T - 1 Bit switching
144 E4 HZ: Limit value exceeded output C - - T - 1 Bit Boolean
144 E4 Heating temperature limit output C - - T - 1 Bit switching
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Muller GS 31.10 knx at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Muller GS 31.10 knx in the language / languages: English as an attachment in your email.

The manual is 1,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Muller GS 31.10 knx

Muller GS 31.10 knx User Manual - English - 2 pages

Muller GS 31.10 knx Installation Guide - German - 55 pages

Muller GS 31.10 knx User Manual - German - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info