683942
15
Zoom out
Zoom in
Previous page
1/55
Next page
TECHNICAL MANUAL GS 3x.10 KNX ENGLISH
15
Number Name Object function C R
W T U Objekt size Data type
145
E4 Store scene
input
C
-
W
-
-
1 Bit
enable
145 E4 Enable save input C - W - - 1 Bit enable
145 E4 switching level 5 output C - - T - 1 Bit switching
145 E4 Switching long actuation output C - - T - 1 Bit switching
145 E4 Bit threshold 1 output C - - T - 1 Bit switching
145 E4 Byte threshold 1 output C - - T - 1 Byte counter pulses (0...255)
145 E4 2 Byte threshold 1 output C - - T - 2 Bytes 2-Byte unsigned value, pulse
145 E4 Temperature threshold 1 output C - - T - 2 Bytes float value, Temperature (°C)
146 E4 Level up/down switching input C - W - - 1 Bit switching
146 E4 ZZ: Limit value exceeded output C - - T - 1 Bit Boolean
146 E4 Send when below threshold 1 input C - W - - 1 Byte counter pulses (0...255)
146 E4 Send when below threshold 1 input C - W - - 2 Bytes 2-Byte unsigned value, pulse
146 E4 Send when below threshold 1 input C - W - - 2 Bytes float value, Temperature (°C)
147 E4 Number actuations input C - W - - 1 Byte counter pulses (0...255)
147 E4 ZZ: Counter reading request input C - W - - 1 Bit switching
147 E4 Send when above threshold 1 input C - W - - 1 Byte counter pulses (0...255)
147 E4 Send when above threshold 1 input C - W - - 2 Bytes 2-Byte unsigned value, pulse
147 E4 Send when above threshold 1 input C - W - - 2 Bytes float value, Temperature (°C)
148 E4 ZZ: Reverse direction input C - W - - 1 Bit Boolean
149 E4 ZZ: reset input C - W - - 1 Bit Boolean
149
E4 Change temperature, tolerance band 1 lower limit
input
C
-
W
-
-
2 Bytes
float value, Temperature (°C)
150 E4 ZZ: Stop input C - W - - 1 Bit Boolean
150 E4 Change temperature, tolerance band 1 upper limit input C - W - - 2 Bytes float value, Temperature (°C)
151
E4 Bit threshold 2
output
C
-
-
T
-
1 Bit
switching
151 E4 Byte threshold 2 output C - - T - 1 Byte counter pulses (0...255)
151 E4 2 Byte threshold 2 output C - - T - 2 Bytes 2-Byte unsigned value, pulse
151 E4 Temperature threshold 2 output C - - T - 2 Bytes float value, Temperature (°C)
152 E4 Send when below threshold 2 input C - W - - 1 Byte counter pulses (0...255)
152 E4 Send when below threshold 2 input C - W - - 2 Bytes 2-Byte unsigned value, pulse
152 E4 Send when below threshold 2 input C - W - - 2 Bytes float value, Temperature (°C)
153 E4 Send when above threshold 2 input C - W - - 1 Byte counter pulses (0...255)
153 E4 Send when above threshold 2 input C - W - - 2 Bytes 2-Byte unsigned value, pulse
153 E4 Send when above threshold 2 input C - W - - 2 Bytes float value, Temperature (°C)
155 E4 Change temperature, tolerance band 2 lower limit input C - W - - 2 Bytes float value, Temperature (°C)
156 E4 Change temperature, tolerance band 2 upper limit input C - W - - 2 Bytes float value, Temperature (°C)
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Muller GS 30.10 knx at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Muller GS 30.10 knx in the language / languages: English as an attachment in your email.

The manual is 1,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Muller GS 30.10 knx

Muller GS 30.10 knx User Manual - English - 2 pages

Muller GS 30.10 knx Installation Guide - German - 55 pages

Muller GS 30.10 knx User Manual - German - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info