5.7 Set threshold for high fever
This thermometer has 38.0℃/100.4℉ preset as an alarm tempera-
ture for high fever. However, 38.0℃/100.4℉ is only a classic
reference value. At this temperature, different people feel different,
with some feeling bad and others not feeling too bad. If you do not
agree with this high fever threshold, after consulting your doctor,
you can manually change it to suit your own situation.
When the thermometer is shut down, press the Set button for about
15 seconds until you see the red status light on the screen, then
release the button. Ignore the other symbols that appear in the
process.
By pressing the Set button, you can increase the threshold by 0.1
℃/0.2℉ each time. The adjustment range is from 38.0℃/100.4℉ to
38.9℃/102.0℉. Once it reaches the Max. value, press the button
again; it will return to the Min. value and the cycle will repeat.
After adjustment is complete, press the button for about 5 seconds
to automatically save the setting and shut down the thermometer.
5.8 Shut down
When the thermometer is turned on, it will shut down automatically
when it is not used for 30 seconds. You can also press the Power
button for 5 seconds to shut down the device manually.
5.9 Replace batteries
When the low battery indicator appears on the screen, slide the
battery cover downward off the shell, take out the two old batteries
and insert two new AAA batteries into the battery compartment
correctly according to the marked polarity symbols. Then close the
battery cover and the thermometer will be restored to normal use.
Take out the batteries if the thermometer will not be used for
more than one month.
!
- 12 -
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MostEssential PC809 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MostEssential PC809 in the language / languages: English as an attachment in your email.

The manual is 0,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info