4.2 Heat insulation
Insulation must comprise heat insulation plates/elements of class A1 in accordance
with DIN 4102 part 1 with a utility temperature limit of 700 °C and a density of more
than 80 kg / m³. The insulation must be labelled in accordance with the relevant insula-
tion code AGI Q 132.
Only the insulation materials given in the table below may be used. If other insulating
materials are used, they must be approved by the relevant supervisory bodies (e.g.:
Promat calcium silicate insulation plate ”Promasil 950 KS, Wolfshöher insulation pla-
te ”Prowolf” Wolfshöher insulation plate ”Vermilite 2000”, Thermax insulation plate
”Thermax SN 400”).
For protection of the building’s external walls and ceilings with a U-value of below 0.4
W / m², extra ventilation (see technical rules for stove and air source heating building
regulations) is required.
*divergent test conditions
The thermal insulation layers must be laid free of moisture and overlapping.
If the thermal insulating materials are to be used on replace inserts without a convec-
tion box, they must be wear-resistant and must not be covered with reective material
(e.g. with black plate, steel plate or galvanised steel). It is essential that the heat insula-
tion has sucient temperature resistance (at least 700 °C), otherwise this can result in
unpleasant odours in the replace/insert.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morso S120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morso S120 in the language / languages: English as an attachment in your email.

The manual is 8,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info