If you have a brick chimney with a large aperture, we recommend that you install an insulat-
ing chimney liner of the proper diameter. This will increase the draught, and improve the
fuel economy.
There are no requirements with respect to specic chimney heights, but a chimney must
be tall enough to provide a good draught, and to ensure that the smoke does not cause any
problems. As a general rule, there will be a satisfactory draught if the chimney extends 4
metres above the stove and at least 100 cm above the spine of the roof.
If the chimney is located along the side of the house, the top of the chimney should never
be lower than the spine of the roof or the highest point on the roof. Please note that there
are often national and local regulations concerning the location of chimneys in houses with
thatched roofs. Please see section 1.9 on Draught.
The chimney and the ue pipe must be tted with cleaning doors, which must be at least
the same size as the chimney’s aperture area.
The chimney must be accessible for external inspection, and it must be possible to access
the cleaning doors and the chimney if it is to
be cleaned from the top
(e.g. steel chimneys).
1.6 Connecting the ue pipe
Lift the upper cast iron top plate o the
stove.
Note: The included round cast iron
cover plate must be mounted on the
upper cast iron top plate if the stove is being
installed with the ue pipe to the rear.
Mounting the ue collar pointing up-
wards
From the factory, the stove is prepared
for installation with the included ue collar (1)
pointing upwards with included ball stop and
screws. The ball stop, which prevents the
chimney sweep from damaging the
stove’s bae plates while sweeping, is the
145 mm long rod that is provided.
Mounting the ue collar to the rear
If the stove is being installed with the
ue pipe to the rear, the round plate
fixed with two screws on the back of the
stove is dismounted. The iron piece on
the inside convection back panel is knocked
out with light, rm taps with a hammer next to the small ”bridges” holding the piece.
The cast iron cover is removed from
the back panel and mounted on the top plate. The ue collar is centred and screwed onto
the back of the stove with the clamps and screws provided. The ball stop is not used when
installing the ue collar to the rear.
The location of the baes
The baes (2) and (3), which are made from vermiculite, are mounted at the factory.
Make sure that the baes are correctly assembled before lighting the stove
(please see the sketch).
B
A
C
C
45°
A
A
SECTION
A-A
SCALE
1 : 10
2
3
1
Zone:
Rev.:
Description
Date
Sign.:
Revisions
Title:
Drawing no.:
1:20
Afstand til brændbart
og snit
Morsø 2800
A4
5766,94
Date of print: 29-06-2018
2800-67 a
Itemno.:
This drawing is Morsø Jernstøberi A/S' property and must not be sold, lended or copied without any written authorization from the company.
Material:
Weight kg.:
Model no.
Drawingtype:
Location of file:
Scale:
Format:
Released:
Construction:
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morso 2800 series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morso 2800 series in the language / languages: English, Danish as an attachment in your email.

The manual is 0,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Morso 2800 series

Morso 2800 series Usermanual and installation guide - German - 11 pages

Morso 2800 series Usermanual and installation guide - Dutch, French - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info