646333
5
Zoom out
Zoom in
Previous page
1/36
Next page
5
SECTION 1 - USERS INSTRUCTIONS
BOILER CONTROLS
Operation
Winter conditions - i.e. CH and DHW required.
Ensure the mode knob control (A) is set to winter ( )
Theboilerwillreandsupplyheattotheradiatorsbutwillgive
priority to DHW on demand.
Summer conditions - i.e. DHW only required.
Set the mode knob control to Summer ( ).
Set the CH external controls to OFF.
Note. The pump will operate briey as a self-check once every 24
hours, regardless of system demand.
Pre-heat is enabled if the pre-heat indicator (F) is lit. To switch
pre-heat on or off move the DHW/Pre-heat control knob (B) fully
clockwise and then return it to the required DHW temperature
setting.
Control of water temperature
Domestic Hot Water
The DHW temperature is limited by the boiler controls to
64
o
C maximum at low draw-off rate, adjustable via the DHW
temperature control (B).
Duetosystemvariationsandseasonaltemperatureuctuations
DHWowrates/temperaturerisewillvary,requiringadjustment
at the draw off tap : the lower the rate the higher the temperature,
and vice versa.
Central Heating
The boiler controls the central heating radiator temperature to a
maximum of 80
o
C and a minimum of 45ºC, adjustable via the CH
temperature control (C).
Theboilerisahighefciencycombinationboilerwhichismost
efcientwhenoperatingincondensingmode.
The boiler will operate in this mode if the CH temperature control
(C) is set to the ‘e’ position (economy mode). This control should
be set to maximum for very cold periods
To shut down the boiler
Set the mode knob control to OFF
To relight the boiler
Repeat the procedure detailed in ‘To light the boiler’.
Frost protection
If the holiday home or park home is to be left unoccupied during
cold periods when there is a threat of freezing, the domestic hot
and cold water circuits must be drained as follows:
- Turn off the cold water supply
- Open all hot and cold water taps
- Open all drain plugs in the hot and cold water system (do not
drainthecentralheatingcircuit,whichshouldhavebeenlled
with antifreeze if installed in a caravan holiday home or park
home).
Refer to the Holiday Home or Park Home owner’s handbook for
the drain plug positions and further instructions on draining down.
Please note there are no drain plugs on the boiler. Leave all taps
and drain plugs open until next use to allow any residual water to
continue to drain.
When installed in a Caravan Holiday Home or Park Home the
heatingcircuitandradiatorsshouldbelledwithanapproved
antifreeze (see section 4.8). The level of antifreeze should be
checked annually by a competent person. If the home is occupied
during very cold and freezing weather, the central heating should
be run continuously and the room stat or thermostatic radiator
valves set at a minimum of 15ºC.
If the home is unoccupied for even a short period, the hot and
cold water system must be drained down. This is the only way to
guarantee against frost damage.
ALL FROST DAMAGE IS OUTSIDE OF THE WARRANTY.
Boiler Overheat Protection
The boiler controls will shut down the boiler in the event of
overheating. Should this occur, a fault code
will be displayed.
Refer to fault chart.
Flame Failure
Should this occur a fault code will be displayed. Refer to fault
chart.
Approx.owtemperaturesfortheboilerthermostatsettingsare:
Knob Setting Flow Temperature
Minimum 40
o
C (104
o
F)
Maximum 64
o
C (147
o
F)
continued . . . . . .
Legend
A. Mode Control Knob
B. DHW/Preheat Control Knob
C. CH Control Knob
D. Boiler Status
E. Burner ‘on’ Indication
F. Pre Heat on/off Indication
G. Mechanical Timer
H. Pressure Gauge
J.
K.
Condensate Drain
Gas Isolation Valve
(on position shown)
A B C D
G
H
J
K
E
F
1
9
20
2
1
2
2
23
24
1
2
3
4
5
6
7
8
9
10
1
1
1
2
1
3
1
4
15
1
6
17
18
0
0
I
preheat
preheat
min
min
max
mode
reset
off
status burner
max
e
Series IIGB24
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morco GB30 SII at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morco GB30 SII in the language / languages: English as an attachment in your email.

The manual is 6,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Morco GB30 SII

Morco GB30 SII User Manual - Dutch - 10 pages

Morco GB30 SII User Manual - French - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info