section 5 - installation instructions
Note.
A 5º or 14º pitched roof plate (not supplied) is required before
proceeding with the installation of this kit.
This kit is suitable for both 5º and 14º pitched roof terminations,
usingaconcentricuetorunverticallyfromthetopoftheboilerand
terminating above roof level.
Connection to the top of the boiler is made using a vertical connector
(supplied in the kit - RSF346).
WEATHER PROOFING
Wheretheuepassesthroughtherooflineanadequatesealmustbe
made. This is achieved by using a suitable sealant.
ACCESSORIES
FlueDuctExtensionKitsareavailableforuelengthsextending
beyond 1m. These packs contain 1m extension ducts and may be
cut to the desired length. If 90º elbows are used (RSF315) they will
reduce the overall height by 1m per elbow.
5.14

Terminal Position Minimum Dimension
Directly below an opening,
air brick, windows, etc. 300 mm
Below plastic / painted gutters 300 mm
Painted surface 300 mm
Below eaves or balcony 500 mm
Below velux windows 2000mm
Above or side of velux windows 600mm
5.15
ASSEMBLING THE ROOF FLUE KIT
1. Positiontheroofplate(suppliedseparately)overtheholecutintheroofandinsertue
terminal from the roof end.
5º & 14º
MAX LENGTH:
7.5m**
**minus any
90º bends
MIN LENGTH:
0.950m
BOILER
2. Ensure that if the length needs to be adjusted to allow an additional 30mm added to
theouterairtubelength14mmaddedtotheinneruelength.Thisallowscorrect
engagement into the vertical connector.
Note. Ensure a square cut. remove all burrs and sharp edges.
3. Fit the vertical connector (supplied in the kit) and secure the vertical connector by
applying downward pressure on the connector.
4. Positiontheclamponthetopfaceoftheuemanifoldandpushithorizontally
backwards.Locatebothclamplugsintotheuemanifoldandsecuretotheue
manifold clamp with the M5 retaining screw.
5. “Push” assembly A into vertical connector.
Notes. Ensure turret sample points are servicable and all caps and plugs are tted.
Ensure condensate siphon/trap is lled with water.
6. Finally ensure the roof plate is correctly sealed to the roof.
Flue Terminal
RSF050
14º
RSF050
1
ASSEMBLY A
Assembly A
5
3
Vertical
connector
4
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morco GB24 SII at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morco GB24 SII in the language / languages: English as an attachment in your email.

The manual is 6,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Morco GB24 SII

Morco GB24 SII User Manual - Dutch - 10 pages

Morco GB24 SII User Manual - French - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info