SECTION 2 - gENERAL SPECIFICATIONS
2.1 GENERAL SPECIFICATIONS
The Morco GB Series II range of boilers are wall mounted, full
sequence, automatic spark ignition low water content, fanned
ue,highefciencycondensingcombinationboilers.
Note.Duetothehighefciencyoftheboileraplumeofwater
vapour will format the terminal during operation. The boiler is
supplied for use with Propane only at 37mbar supply pressure. It
is particularly suitable for caravan holiday home and park home
use.
Maximum heat output in either heating or hot water for the GB24
is 24.2kW (82,570 Btu/hr)
Maximum heat output in heating mode for the GB30 is 24.2 kW
(82,570 Btu/hr) with 30.3 kW (103,384 Btu/hr) available for hot
water production.
Theboilercanbesuppliedwithastandardconcentricuewith
additionalextensions,uedeectorandverticaluekitsavailable
asoptionalextras.TheonlyueSthatcanbettedarethose
detailed in this instruction manual.
The boiler is suitable for connection to fully pumped, sealed
heating systems ONLY. Adequate arrangements for completely
draining the system by provision of drain cocks must be provided
in the installation pipework.
The boiler contains the following components:
Cast Aluminium Heat Exchanger
Domestic Hot Water Plate Heat Exchanger
Diverter Valve
Circulating Pump
Pressure Gauge
Safety Valve and Central Heating Expansion Vessel
Automatic Bypass
Daily Pump and Diverter Valve Exercise
Mechanical 24hr Timer
The boiler temperature controls are visible, located in the control
panel. These enable the user to control both CH and DHW
temperatures independently. There is the additional feature of a
DHW preheat facility. Operating and fault codes are displayed on
the status panel.
1 Expansion Vessel
2 Pump
3 Auto Air Vent
4 Water Pressure Switch
5 Flow Thermistor
6 Return Thermistor
7 Divertor Valve
8 Fan
9 Venturi
10 DHW Plate Heat Exchanger
11 Ignition Electrode
12 Flame Detection Electrode
13 Gas Valve
14 Siphon / Trap
15 DHW Flow Turbine
16 System Pressure Gauge
17 Sump Cover
Schematic Diagram
8
11
5
9
13
4
7
17
15
10
3
6
2
1
14
12
16
8


Need help? Post your question in this forum.

Forumrules
1

Forum

morco-gb24-series-ii

Reset search

  • We have this Boiler fitted in our Caravan and not had a trouble till we had the boiler serviced since then the boiler will deal with the hot water but if you put it onto timer for the central heating the boiler comes in and when it gets to temperature goes out but then when the temperature drops the boiler does not come back in and shows L-2 which means it’s locked out please advice what can be the trouble thankyou Submitted on 10-11-2021 at 19:52

    Reply Report abuse
  • Je voudrais savoir pourquoi s affiche sur l écran de contrôle F 9 qui clignote. Et pas d eau chaude. Submitted on 29-6-2021 at 18:11

    Reply Report abuse
  • Hot water working but no heating and no fault codes Submitted on 12-4-2021 at 18:39

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morco GB24 Series II at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morco GB24 Series II in the language / languages: English as an attachment in your email.

The manual is 6,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info