646343
7
Zoom out
Zoom in
Previous page
1/20
Next page
7
The Fagor FEB-24E is a wall hung, room sealed,
fan assisted, microprocessor controlled fully modu-
lating gas combination boiler for providing both cen-
tral heating and domestic hot water. It is particularly
suitable for Caravan Holiday Home and Park Home
use. Maximum heat output in either heating or hot
water mode is 23.7.kW (80.840 Btu/h), and priority is
always given to the supply of hot water.
NOTE: The central Heating power is factory set at
70% of its maximum.
The appliance is supplied with a standard concentric
air/flue duct and wall terminal, however additional
extension kits, vertical flue kit are available as
optional extras.
The appliance is intended for use with sealed central
heating systems and is supplied for use with
propane gas.
The appliance includes the following components:
Induced draught fan for the extraction of combus-
tion products and induction of combustion air.
Modulating gas valve with double safety valves
Circulation pump with manual anti-seizure device
Central heating expansion vessel.
Differential air pressure switch. Prevents the boil-
er firing if there is insufficient air supply due to a fault
or blockage.
Water pressure switch. Prevents the boiler firing if
there is less than 0.8 bar in the system.
Thermistors (NTC) There are two thermistors fitted
for automatic control of the domestic hot water and
the central heating flow temperature.
Safety thermostat Shuts down the boiler in the
event of overheating. Resets after a few minutes
cooling
Electronic controls, incorporating the following fea-
tures:
- Temperature selection for central heating from
between 60 to 85°C.
- Temperature selection for domestic hot water from
between 35 to 60°C.
- Continuous modulation of the gas valve.
- Flame control by ionisation
- Ignition control
- Anti-frost control in the central heating circuit.
- Anti - seizure of the pump.
2.- GENERAL SPECIFICATIONS
Schematic diagram- Hydraulic circuit
1.- Expansion vessel
2.- Pump with Automatic air bleed
3.- Water pressure switch
4.- Central heating thermistor
5.- Three way valve
6.- Overheat thermostat
7.- Air pressure switch
8.- Venturi
9.- Fan
10.- Sealed air box
11.- Copper heat exchanger
12.- Combustion chamber
13.- Ignition electrode
14.- Burner
15.- Flame sensing electrode
16.- Modulating gas valve
17.- Gas inlet
18.- D.H.W Thermistor
19.- Hot Water outlet
20.- Plate heat exchanger
21.- C.H flow
23.- Cold water inlet
24.- C.H return
25.- Pressure relief valve
26.- Automatic By-pass
27.- Expansion vessel valve
28.- Draining valve
1
3
4
7
5
6
8
9
10
11
12
13
14
15
16
17
18
19
20
21
23
24
25
26
27
28
2
A pre-winter check of the amount of antifreeze protection is strongly recommended. The level may
have fallen due to leaks in the system requiring frequent refilling from the filling loop.
7


Need help? Post your question in this forum.

Forumrules
1

Forum

morco-feb-24e-uk-supercompact

Reset search

  • Can anyone tell me why my pump is running continuously? Morco 24ed Submitted on 15-10-2020 at 10:10

    Reply Report abuse
  • What anti freeze should be used in winter conditions Submitted on 19-1-2020 at 12:35

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morco FEB-24E UK SUPERCOMPACT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morco FEB-24E UK SUPERCOMPACT in the language / languages: English as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Morco FEB-24E UK SUPERCOMPACT

Morco FEB-24E UK SUPERCOMPACT User Manual - French - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info