646335
9
Zoom out
Zoom in
Previous page
1/22
Next page
• GAS CONSUMPTION
GAS PRESSURE AT
TIPE OF GAS GAS FLOWAT 15ºC and 760 mm Hg APPLIANCE INLET
(Standarised gases) (mbar)
G11E D61B-D61E
Butane 1,8 kg/h. 0,88 kg/h. 28-30
Propane 1,8 kg/h. 0,88 kg/h. 37
Natural 2,3 m
3
/h. 1,2 m
3
/h. 20-25
PIPE WORK CONNECTION SIZES
GAS Butane/Propane-Natural 10 or 15 mm.
WATER Inlet (cold) 15 mm.
Outlet (hot) 15 mm.
Flueway D61B and D61E ø 90 mm.
G11E ø 110 mm.
• PIPE WORK DIAMETERS AND CONNECTION SIZES
• BURNER PRESSURE
9
TIPE OF GAS
(Standarised gases)
G11E D61B-D61E
Butane 27,5 mbar 29 mbar
Propane 36,3 mbar 36,9 mbar
Natural gas 16,4 mbar 19,4 mbar
• BURNT GAS FLOW AND SMOKE TEMPERATURES
MODELS G11E D61B-D61E
Flow g/s 13 7,8
Temperature 160ºC 137ºC
• AIR FLOW NECESSARY FOR THE COMBUSTION
TIPE OF GAS
(Standarised gases)
G11E D61B-D61E
Butane (1Kg.) 20,31 m
3
/h. 10,75 m
3
/h.
Propane (1Kg.) 20,63 m
3
/h. 10,92 m
3
/h.
Natural gas (1 m
3
) 23,27 m
3
/h. 12,14 m
3
/h.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morco D-61B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morco D-61B in the language / languages: English as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Morco D-61B

Morco D-61B User Manual - Dutch - 23 pages

Morco D-61B User Manual - French - 23 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info