3-TECHNICAL
DATA
24CPM
JOCPM
Unit
Gas
Category*
I I
2H3i>
II
21m
Boiler
Type
CrJ<~J·
Ci*l•
C4:3<¥lt
c
IJCxh
C:Jl!.liol•
c4l(X)•
C.s:JW,
C,)(:(,)t
Cal(xJ
Cnt«>t
C'i<xl>
Ct~(~
Type
of
gas
G 20 G
31
G20
031
Performances
CH
Min. Heat Output (80160
°C)
6,6
7,9
8, I
9,6
kW
CH
Max. Heat Output (80160 °C)
22.2
22,2
27,3
27,3
kW
CH
Min. Heat Output (50/30 °C)
7,3
8,8
9
10,8
kW
CH Max.
Heat
Output (50130 °C)
24
24
30
30
kW
CH
Min. Heat Input
6,8
8,2
8,4
10
kW
CH
Max. Heat Input
22,8
22,8
28
28
kW
DHW
Min. Heat Output
6,7
8
8,2
9,7
kW
DHW Max. Heat Output
26
26
31
31
kW
DHW
Min. Heat lnput
6,8
8,2
8,4
10
kW
DHW
Max. Heat Input
27
27
32
32
kW
Gas
Consumption**
Natural Gas (Max. Load)
2,38 2,92
m
3
lh
Natural Gas (Min. Load)
0,71
0,88
m3/h
Propane (Max. Load)
1,77 2,17
kglh
Propane (Min. Load)
0,64
0,77
kglh
Gas
Supply
Pressure
20 20
mbar
Natural Gas (G 20)
37
37
mbar
Propane (G 31)
Domestic
Hot
Water
Min. Flow
Rate
For Activating
3 3
Jtr/min
Max.
Flow
Rate
12
(~t=JI
•c)
14
(~t=32
.,C)
I trim in
Flow rate at 35
°C
temp. rise
10,6 12,7
ltr/min
Min. Operating Pressure
0,2 0,2
bar
Max. Operating Pressure
7
7
bar
Set Temperature Range
35-60 35-60
oc
Central
Heating
0,8 0,8
Min. Operating Pressure
bar
Max. Operating Pressure
3 3
bar
Set
Temperature Range
30-80 30-80
oc
General
Electrical Supply
230V AC- 50Hz 230V AC- 50Hz
VAC/Hz
Fuse Rating
4A
4A
A
Electrical Power Consumption
115
115
watt
Expansion Vessel
7 7
ltr
Dimensions (HxWxL)
775 x454x370 775 x454x370
mm
Weight (Net)
40 40,5
kg
Seasonal Efficiency (SEDBUK)
90,0-NG
I 91,3-LPG 90,1-NG I 91,6-LPG
%
IP rating
IPX40
IPX40
**For gas
consumption-
Calorific Value (Net) Natural gas: 34.52 MJim
3
Propane: 78.5 MJim
3
}>
c type boilers
(Crl(XJ,
c33(s),
c43{xh
CsJ(x),
c63(x),
C8J(x))
are air independent gas appliances. Air required for
combustion is provided from outside via air
supp!yducts
with products
of
combustion, discharged by flue
gas
ducts.
Only
M
OR
CO
supplied
flue options
may
be
used.
I
11
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morco 24CPM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morco 24CPM in the language / languages: English as an attachment in your email.

The manual is 7,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info