632632
55
Zoom out
Zoom in
Previous page
1/60
Next page
-51-
APPENDIX 2 PIN CONFIGURATION
PIN FUNCTION DESCRIPTION
1
RS232-TX
DVR can be controlled remotely by the keyboard of PC by using RS-232 serial communication
signals. Please refer to “APPENDIX 3 RS-232 PROTOCOL” for details.
2
RS232-RX
DVR can be controlled remotely by the keyboard of PC by using RS-232 serial communication
signals. Please refer to “APPENDIX 3 RS-232 PROTOCOL” for details.
3 ~ 6
ALARM INPUT
To connect the wire from ALARM INPUT ( PIN 3 -- 6 ) to GND ( PIN 9 ) connector, DVR will start
recording and the buzzer will be on.
“MENU -> ADVANCE -> DETECTION -> ALARM” is set to “Low”:
When the alarm input signal is “ Low ”, the unit starts to record and buzzer.
“MENU -> ADVANCE -> DETECTION -> ALARM” is set to “High”:
When the alarm input signal is “ High ”, the unit starts to record and buzzer.
7
EXTERNAL ALARM NC
Under the normal operation, COM connects with NC and disconnects from NO. But when any
alarm is triggered, COM disconnects with NC and connects with NO.
Attention: The voltage restriction is under DC24V 1A.
8
EXTERNAL ALARM NO.
Under the normal operation, COM disconnects with NO. But when any alarm is triggered, COM
connects with NO.
Attention: The voltage restriction is under DC24V 1A.
9
GND
Signal GND
10
RS485-B
DVR can be controlled remotely by the keyboard of PC by using RS-485 serial communication
signals.
11
RS485-A
DVR can be controlled remotely by the keyboard of PC by using RS-485 serial communication
signals.
12 ~ 13
PIN OFF
14
ALARM RESET
Connecting the wire from ALARM RESET (PIN 14) to GND (PIN 9) connector will disable alarms.
A
n external signal to ALARM RESET (PIN 14) can be used to reset both ALARM OUTPUT signal
and DVR’s internal buzzer. When any alarm has been triggered, the signal becomes “Low”, and
all alarm activities will be stopped. Under the normal operation, the signal remains “High”.
15
EXTERNAL ALARM COM
Under the normal operation, COM disconnects with NO. But when any alarm is triggered, COM
connects with NO.
Attention: The voltage restriction is under DC24V 1A.
16 ~ 17
GND
Earth GND
Magnetic Contact: When the ma
g
netic contact
is opened, the alarm will be triggered and the
recording is on.
Siren: When the DVR is triggered by alarm or
motion, the COM connects with NO and the siren
with strobe starts wailing and flashing.
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Monacor DMR524 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Monacor DMR524 in the language / languages: English as an attachment in your email.

The manual is 3,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Monacor DMR524

Monacor DMR524 Quick start guide - English, German - 80 pages

Monacor DMR524 User Manual - German - 56 pages

Monacor DMR524 Quick start guide - French - 80 pages

Monacor DMR524 User Manual - French - 56 pages

Monacor DMR524 Quick start guide - Italian, Portuguese, Spanish - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info