21
8.2 HOW TO ACTIVATE THE OUTDOOR ALARM
In order to switch on (arm) the Mobeye Outdoor Alarm:
- Hold a tag briefly against the tag reader, after which
the exit indication starts. The exit time takes 120
seconds; hereinafter the sensor is active. In the first 20
seconds, the red LED in the sensor flashes.
In order to switch off (disarm) the Mobeye Outdoor Alarm:
- Hold a tag briefly against the tag reader. A short beeps are heard to
indicate a correct disarming. After a few (max. 15) seconds three beeps
sound which indicates that the system has fully completed the disarming
process.
In the disarmed status the Mobeye Outdoor Alarm will not send alarm
notifications. The unit remains active and is able to switch on time-
controlled and to send test and 'low battery voltage' messages.System reset
8.3 SYSTEM RESET
1. Remove / disconnect the batteries.
2. Keep (an enrolled) tag against the outside button while reinserting the
batteries. Keep it pressed for (about) another 5 seconds.
3. Release the tag immediately after the LED starts to flash.
4. If relevant, connect the battery pack.
5. Re-enroll the tags (see chapter 6).
After a successful reset, the status LED will blink green to indicate that the
module is not configured. The security code is back to factory settings as
well.