sent. The module continues operating albeit in the low power mode. This
means the communication module switches off and only establishes
network connection when it needs to send an
alarm notification, test message or low battery
alert.
Connect the power adapter (or any other
regulated 12-24V DC power supply) to the
power input of the connector (press on the
green pins to connect the wires).
Mobeye adapter 10027 position
- V+ to “+” black lead with white stripe left
- Ground to “- black lead 2nd from left
3.5 CONNECT A SENSOR TO THE INPUT (OPTIONALLY)
Two external sensors can be
connected to the inputs.
Insert the 2 wires of an external
sensor through the swivel and
insert them in the two connectors
of input 1 (press on the green IN1
pins for connecting the wires). It
does not matter which wire is
connected to which connector.
A second sensor may be
connected to input 2 (IN2).
As default the input is programmed as Normally Open (NO) contact. This
means the input is triggered if the input is closed for at least 1 second. In
case the contact is Normally Closed (NC), see paragraph 5.10. If the sensor
needs to be activated for a longer period before triggering an alarm, see
5.10.
3.6 CONNECT A DEVICE TO THE OUTPUT (OPTIONALLY)
The Mobeye CML4275 has an open collector output, left of the DC-IN,
which switches after receiving a specific SMS or after an alarm. The output
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mobeye CML4275 - ThermoGuard Twinlog at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mobeye CML4275 - ThermoGuard Twinlog in the language / languages: English as an attachment in your email.

The manual is 0.48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Mobeye CML4275 - ThermoGuard Twinlog

Mobeye CML4275 - ThermoGuard Twinlog User Manual - German - 36 pages

Mobeye CML4275 - ThermoGuard Twinlog User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info