When set to “ALARM”, notifications are sent to the set contacts. When using
your own SIM card, the setting “ALERT” only results in an SMS notification to
TEL1. The default setting is "OFF" for portal use and “ALERT” for own SIM
cards.
5.8 POWER FAILURE DELAY TIME
To avoid false alarms caused by short power failures, a power failure delay
time can be set. This defines the time between the initial power failure and
the alarm notification. If the power is restored within the delay time, no
alarm is sent. The time can be set between 0 and 999 minutes. As default, the
delay time is set to "0".
5.9 CALL AND/OR SMS (OWN SIM CARDS)
When using your own SIM card, by default the Panic Button will call and
send SMS text messages. It is possible to suppress one of these. By turning
off the CALL, the unit will only send SMS text messages. By turning off the
SMS, it will only call. The default both values are set to "ON".
5.10 PRIORITY OF THE MESSAGE (OWN SIM CARDS)
This setting is only relevant once using your own SIM card. In the event of an
alarm, the Mobeye Panic Button will first send an SMS notification and then
call the contacts. The priority can be changed to CALL first. By default, the
priority is MESSAGE (SMS is sent first).