604737
15
Zoom out
Zoom in
Previous page
1/24
Next page
–14–
Airflow direction adjustment
PROGRAM TIMER operation
The timer operations of the combination of ON and OFF TIMER. Once this has been set the timer operations will be repeated at the same time every
day unless the ON/OFF button is pressed.
Example: When it is prefered to stop at 22:30, and then start operation at 8:00, near the
set temperature.
OFF TIMER operation setting
Set by the procedures on page 12. Set to
ON TIMER operation setting
Set by the procedures on page 13. Set to
Timer light (yellow) on the unit will light when the setting is completed.
The set time will be displayed on the remote control unit. The display will
change depending on the operational status.
How to cancel
Press the CANCEL button to turn off the timer display.
Changing of set time
Set a new time by using the OFF TIMER or ON TIMER button.
Comfort Start-up
In ON TIMER operation, the unit starts the operation a little earlier, so that the
room can approach optimum temperature at ON time. This is so called
“Comfort start-up”.
Mechanism
The room temperature is checked
60 minutes before the ON time.
Depending on the temperature at
that time, the operation starts 5 to
60 minutes before the timer is at
ON.
The function is available for both
COOL and HEAT operation
mode (including AUTO). It does
not work for DRY mode.
SLEEP TIMER
In COOL operation
(Stop) Operation starts
Check the room
temp. 60 mins.
before.
Set time
When SLEEP TIMER is selected, the set temperature is automatically
adjusted after a while, ensuring that the room is not too cold during cooling or
too warm during heating.
During cooling : The preset temperature is lowered by 1°C at the start of
SLEEP operation (when the timer is set). After that, the temperature goes
up by 1°C every an hour to become 1°C higher than the present
temperature.
During heating: The preset temperature is lowered by 1°C at the start of
SLEEP operation (when the timer is set). After that the temperature be-
comes 3°C lower in an hour and 6°C lower in two hours than the present
temperature.
(Operation)
Set temperature
With ON TIMER, the air conditioner starts running. Then,
with OFF TIMER, the air conditioner stops running.
With OFF TIMER, the air conditioner stops running. Then,
with ON TIMER, the air conditioner starts running.
Adjusting up/down air flow direction
Air flow direction adjustment can not be performed, although a display will be changed if
"AIR FLOW" button is pushed.
RJD012A200G_EN_001-022 4/21/14, 13:4314
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mitsubishi SRR60ZJ-S1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mitsubishi SRR60ZJ-S1 in the language / languages: English as an attachment in your email.

The manual is 2,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Mitsubishi SRR60ZJ-S1

Mitsubishi SRR60ZJ-S1 User Manual - German - 24 pages

Mitsubishi SRR60ZJ-S1 User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info