604723
18
Zoom out
Zoom in
Previous page
1/34
Next page
–17–
ALLERGEN CLEAR operation
Aim the remote control at the air-conditioner.
Press the ALLERGEN CLEAR button.
1
The power of enzymes is used to eliminate allergy-causing allergens that accu-
mulate on the allergen clear filter.
To stop:
Press the ON/OFF or
ALLERGEN CLEAR button.
Since the room temperature may change quite a bit, it is recommended
that this be used when no one is in the room. (It completes automati-
cally in approximately 90 min.)
During ALLERGEN CLEAR operation temperature, fan speed, airflow
direction and timer operations settings cannot be made.
In case of SCM multi system, ALLERGEN CLEAR control function is
invalid.
In case of SCM multi system, if ALLERGEN button is pressed by mistake,
the indoor unit which received such command stops.
NOTE
ON-TIMER + OFF-TIMER operation
The timer operations of the combination of ON and OFF-TIMER.
Example: When it is prefered to stop at 22:30, and then start operation at 8:00, near the set
temperature.
OFF-TIMER operation setting
Set by the procedures on page 15. Set to
ON-TIMER operation setting
Set by the procedures on page 16. Set to
Timer light (yellow) on the unit will light when the setting is completed.
The set time will be displayed on the remote control. The display will change de-
pending on the operational status.
Comfort Start-up
In ON-TIMER operation, the unit starts the operation a little earlier, so
that the room can approach optimum temperature at ON time. This is
so called “Comfort start-up”.
Mechanism
The room temperature is
checked 60 minutes before
the ON time. Depending on
the temperature at that time,
the operation starts 5 to 60
minutes before the timer is at
ON.
The function is available for
both COOL and HEAT opera-
tion mode (including AUTO).
It does not work for DRY
mode.
SLEEP TIMER
In COOL operation
(Stop) Operation starts
Check the room
temp. 60 mins.
before.
Set time
When SLEEP TIMER is selected, the set temperature is automatically
adjusted after a while, ensuring that the room is not too cold during
cooling or too warm during heating.
During cooling : The preset temperature is lowered by 1°C at the
start of SLEEP operation (when the timer is set). After that, the tem-
perature goes up by 1°C every an hour to become 1°C higher than
the present temperature.
During heating: The preset temperature is lowered by 1°C at the
start of SLEEP operation (when the timer is set). After that the tem-
perature becomes 3°C lower in an hour and 6°C lower in two hours
than the present temperature.
(Operation)
Set temperature
With ON-TIMER, the air conditioner starts running. Then,
with OFF-TIMER, the air conditioner stops running.
(Example Present time : 5:00 The air conditioner stopping.)
With OFF-TIMER, the air conditioner stops running. Then,
with ON-TIMER, the air conditioner starts running.
(Example Present time : 20:00 The air conditioner running.)
How to cancel
Press the CANCEL button to turn off the timer display.
Changing of set time
Set a new time by using the OFF-TIMER or ON-TIMER button.
RKW012A412D_EN_001-032 4/15/14, 13:5517
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mitsubishi SRK80ZM-S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mitsubishi SRK80ZM-S in the language / languages: English as an attachment in your email.

The manual is 4,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Mitsubishi SRK80ZM-S

Mitsubishi SRK80ZM-S User Manual - German - 34 pages

Mitsubishi SRK80ZM-S User Manual - Dutch - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info