604711
92
Zoom out
Zoom in
Previous page
1/103
Next page
-
91
-
'13 • SRK-T-144
Connecting the indoor unit's connection cable to the interface
Remove
the upper
case
Connect the indoor unit's
connection cable
Fix the cable with the
cable clamp
Name of each part of the interface
Terminal for indoor unit's
connection cable
Terminal block for wired
remote control*
CNT terminal
Clamp for clamping the connection
cable for wired remote control*
ROM terminal
Wiring inlet
(top or back)
DIP switch (SW2) : [Factory setting : all ON]
DIP switch (SW3) : [Factory setting : all OFF]
Rotary switch (SW1) for address setting
Terminal block for super link E board (SC-ADNA-E)*
Clamp for clamping the connection cable for
super link E board (SC-ADNA-E)*
*Either the connection cables of super link E board (SC-ADNA-E) or of wired remote control is connectable.
Accessories included in package
Be sure to check all the accessories included in package.
Part name
Quantity
No.
Installation must be carried out by a qualified installer.
If you install it by yourself, it may cause an electric shock, fire and personal injury , as a result of a system malfunction.
Install it in full accordance with the instruction manual.
Incorrect installation may cause an electric shock, fire and personal injury.
Electrical work must be carried out by a qualified electrician in accordance with the technical standard for electrical equipment, the
indoor wiring standard and this instruction manual.
Incorrect installation may cause an electric shock, fire and personal injury.
Use the specific cables for wiring. And connect all the cables to terminals or connectors securely and clamp them with cable clamps in
order for external forces not to be transmitted to the terminals directly.
Incomplete connection may cause malfunction, and lead to heat generation and fire.
Use the original accessories and specified components for installation.
If the parts other than those prescribed by us are used, it may cause an electric shock, fire and sersonal injury.
WARNING
Warning
Always go along these instruction.
Safety precautions
Before use, please read these Safety Precautions thoroughly
before installation.
All the cautionary items mentioned below are important safety related items to be taken
into consideration, so be sure to observe them at all times.
Incorrect installation could lead to serious consequences such as death, major
injury or envirommental destruction.
Symbols used in these precautions
After completed installation, carry out trial operation to confirm no anomaly, and ask the
user to keep this installation manual in a good place for future reference.
Indoor unit's connection cable (cable length: 1.8m)
Wood screws (for mounting the interface: ø4x 25)
Tapping screws (for the cable clump and the interface mounting bracket)
Interface mounting bracket
Cable clamp (for the indoor unit's connection cable)
1
2
3
1
1
CNT terminal connection cable (total cable length: 0.5m)
1
*
Interface board
Clamp for clamping indoor
unit's connection cable
Switch
SW2-1
SW2-2
Setting
ON**
OFF
ON**
OFF
Function
CNT level input
CNT Pulse input
Wired remote control : Enable
Wired remote control : Disable
Switch
SW2-3
SW2-4
Setting
ON**
OFF
ON**
OFF
Function
External input (CNT input)
Operation permission/prohibition (CNT input)
Annual cooling : Enable***
Annual cooling : Disable***
** Factory setting *** Indoor fan control at low outdoor air temperature in cooling
Remove the upper case of the interface.
• Remove 2 screws from the interface casing before removal of upper casing.
Connect the indoor unit's connection cable to the interface.
• Connect the connector of the indoor unit connection cable to the
connector on the interface’s circuit board.
Fix the indoor unit's connection cable with the cable clamp.
• Cable can be brought in from the top or from the back.
• Cut out the punch-outs for the connection cables running into the casing with cutter.
Connect the indoor unit's connection cable to the indoor control PCB.
• Connect the indoor unit's connection cable to the indoor control PCB securely.
• Clamp the connection cable to the indoor control box securely with the cable clamp
provided as an accessory.
• Regarding the cable connection to the indoor unit, refer to the instruction manual for
indoor unit.
* SC-BIKN-EA only
(2) Interface kit (SC-BIKN-E)
RKZ012A088B
92


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mitsubishi SRK50ZMX-S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mitsubishi SRK50ZMX-S in the language / languages: English as an attachment in your email.

The manual is 21,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Mitsubishi SRK50ZMX-S

Mitsubishi SRK50ZMX-S User Manual - English - 34 pages

Mitsubishi SRK50ZMX-S User Manual - German - 34 pages

Mitsubishi SRK50ZMX-S User Manual - Dutch - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info