7
-
'13 • SRK-T-144
Model
Item
SRK60ZMX-S
Indoor unit SRK60ZMX-S Outdoor unit SRC60ZMX-S
Power source Single phase, 220 - 240V, 50Hz
Operation
data
Nominal cooling capacity (range) kW 6.1 ( 1.1 (Min.) - 6.8 (Max.))
Nominal heating capacity (range) kW 6.8 ( 0.6 (Min.) - 8.2 (Max.))
Power
consumption
Cooling
kW
1.87 ( 0.2 - 2.50 )
Heating 1.67 ( 0.2 - 2.70 )
Max power consumption 2.9
Running
current
Cooling
A
8.6 / 8.2 / 7.9 (220/ 230/ 240 V)
Heating 7.7 / 7.3 / 7.0 (220/ 230/ 240 V)
Inrush current, max current 8.6 / 8.2 / 7.9 (220/ 230/ 240 V) Max. 15
Power factor
Cooling
%
99
Heating 99
EER Cooling 3.26
COP Heating 4.07
Sound power level
Cooling
dB(A)
64 65
Heating 64 64
Sound pressure level
Cooling Hi: 51 Me: 41 Lo: 29 ULo: 25 54
Heating Hi: 48 Me: 41 Lo: 34 ULo: 27 54
Silent mode sound pressure level Cooling:45 / Heating:45
Exterior dimensions (Height x Width x Depth) mm 309 x 890 x 220 640 x 800(+71) x 290
Exterior appearance
( Munsell color )
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
Net weight kg 13.5 45
Compressor type & Q'ty RMT5113MCE2( Twin Rotary type ) x 1
Compressor motor (Starting method) kW 1.50 ( Inverter driven )
Refrigerant oil (Amount, type)
0.45 (DIAMOND FREEZE MA68)
Refrigerant (Type, amount, pre-charge length) kg R410A 1.5 in outdoor unit (incl. the amount for the piping of 15m )
Heat exchanger Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Fan type & Q'ty Tangential fan x 1 Propeller fan x 1
Fan motor (Starting method) W 30 x1 (Direct drive) 34 x1 (Direct drive)
Air flow
Cooling
m
3
/min
Hi: 14.5 Me: 12.5 Lo: 8.5 ULo: 7.0 41.5
Heating Hi: 17.5 Me: 15.0 Lo: 11.0 ULo: 8.5 39.0
Available external static pressure Pa 0 0
Outside air intake Not possible
Air filter, Quality / Quantity Polypropylene net ( washable ) x 2
Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)
Electric heater
Operation
control
Remote control Wireless remote control
Room temperature control Microcomputer thermostat
Operation display RUN: Green, TIMER: Yellow, HI POWER: Green, 3D AUTO: Green, ECONO: Blue
Safety equipments
Compressor overheat protection, Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Installation
data
Refrigerant piping size (O.D) mm Liquid line :
φ
6.35 (1/4") Gas line :
φ
12.7 (1/2")
Connecting method Flare connection Flare connection
Attached length of piping m Liquid line : 0.55 / Gas line : 0.49
Insulation for piping Necessary (Both sides), independent
Refrigerant line (one way) length m Max. 30
Vertical height diff. between O.U. and I.U.
m Max. 20 (Outdoor unit is higher) / Max. 20 (Outdoor unit is lower)
Drain hose
Hose connectable ( VP 16 ) Holes
φ
20 x 5 pcs
Drain pump, max lift height mm
Recommended breaker size A 16
L.R.A. (Locked rotor ampere) A 8.6 / 8.2 / 7.9 (220/ 230/ 240 V)
Interconnecting wires Size x Core number 1.5mm
2
x 4 cores (Including earth cable) / Terminal block (Screw fixing type)
IP number IPX0 IPX4
Standard accessories
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)
Option parts Interface kit (SC-BIKN-E)
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature Outdoor air temperature
Standards
DB WB DB WB
Cooling 27˚C 19˚C 35˚C 24˚C
ISO5151-T1
Heating 20˚C 7˚C 6˚C
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3)
Sound level indicates the value in an anechoic chamber. During operation these value are somewhat higher
due to ambient conditions.
(4) Select the breaker size according to the own national standard.
The pipe length is 7.5m.
B
RWA000Z252
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mitsubishi SRK35ZMX-S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mitsubishi SRK35ZMX-S in the language / languages: English as an attachment in your email.

The manual is 21,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Mitsubishi SRK35ZMX-S

Mitsubishi SRK35ZMX-S User Manual - English - 34 pages

Mitsubishi SRK35ZMX-S User Manual - German - 34 pages

Mitsubishi SRK35ZMX-S User Manual - Dutch - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info