664856
11
Zoom out
Zoom in
Previous page
1/144
Next page
-
8
-
Item
Models
SCM48ZG-S SCM60ZG-S
Cooling capacity W 4800 (1100~6900) 6000 (1100~7500)
Heating capacity W 6000 (1400~7100) 7000 (1400~7600)
Power source 1 Phase 220/230/240V 50Hz
Power consumption
Cooling
W
1190 (200~2350) 1620 (400~3050)
Heating 1380 (180~2030) 1740 (390~2620)
Running current
Cooling 5.5/5.2/5.0 7.4/7.1/6.8
Heating
A
6.3/6.1/5.8 8.0/7.6/7.3
Sound level Cooling : 48 Heating : 49 Cooling : 48 Heating : 50
Noise level
Power level
dB
Cooling : 63 Heating : 64 Cooling : 63 Heating : 65
Exterior dimensions
Height × Width × Depth
mm
640 × 850 × 290
Color Stucco white
Net weight kg 47 51
Refrigerant equipment
Compressor type & Q’ty
[Scroll] × 1 [Twin rotary] × 1
Motor kW 0.7 1.3
Starting method Direct start
Refrigerant control Capillary tubes + Electronic expansion valve
Refrigerant kg
R410A 1.95 (Pre-charged up to the piping length of 40m) R410A 2.2 (Pre-charged up to the piping length of 30m)
Refrigerant oil R 0.48 (RB68A) 0.67 (MEL56)
Air handling equipment
Fan type & Q’ty
Propeller fan × 1
Motor W 34
Air flow (at high) CMM 42
Shock & vibration absorber Rubber (for compressor)
Safety equipment
Size × Core × Number mm (in)
Liquid line: φ 6.35 (1/4) × 3
Gas line: φ 9.52 (3/8) × 3
Connecting method Flare connecting
Attached length piping
Insulation Necessary (Both Liquid & Gas lines)
Power source supply Terminal block (Screw fixing type)
Size × Core number 1.5 mm
2
× 4 cores (Including earth cable) × 3
Connecting method Terminal block (Screw fixing type)
Accessories (included)
Union : (φ 9.52 / φ 12.7) × 2
Installation sheet, Manual instruction
Installation sheet, Manual instruction
SKM20, 22, 25, 28, 35 type SKM20, 22, 25, 28, 35, 50, 60 type
Indoor units to be combined STM25, 35 type STM25, 35, 50, 60 type
SRRM25, 35 type SRRM25, 35, 50, 60 type
Compressor overheat protection, Overcurrent protection
Serial signal error protection
Notes (1) The data are measured at the following conditions.
Refrigerant
piping
Connection
wiring
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27°C 19°C 35°C 24°C ISO-T1, JIS C9612
Heating 20°C C 6°C ISO-T1, JIS C9612
(2) The values for capacity and power consumption shown in a range ( ) indicate the minimum and maximum of the range.
(3) If the piping length exceeds 30 m, additional charging is required. (20g/m, SCM60ZG-S)
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mitsubishi SKM25ZG-S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mitsubishi SKM25ZG-S in the language / languages: English as an attachment in your email.

The manual is 6,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Mitsubishi SKM25ZG-S

Mitsubishi SKM25ZG-S User Manual - German - 24 pages

Mitsubishi SKM25ZG-S User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info