587226
13
Zoom out
Zoom in
Previous page
1/24
Next page
12
7 Press SET button (Fixing of the upper
limit position)
The upper limit position is fixed and the setting position is
displayed for two seconds. Then proceed to lower limit position
selection display.
[EXAMPLE]
” (lights for two seconds)
” (shows current setting)
8 Press or button (Selection of lower limit
position)
Select the lower limit position of louver.
“position 1” is the most horizontal, and “position 6” is the most
downwards.
“position
--
” is to return to the factory setting. If you need to
change the setting to the factory setting, use “position
--
”.
” (the most horizontal)





” (the most downwards)

” (return to the position of shipment)
9 Press SET button (Fixing of the lower limit
position)
The upper limit position and lower limit position are fixed, the set
positions lights for two seconds, and then the setting is completed.
After the setting is completed, the louver which was set
moves from the original position to the lower limit position,
and goes back to the original position again. (This operation
is not performed if the indoor unit and/or indoor unit fan is in
operation.)
[Example]
” (lights for two seconds)
10
Press button.
Louver adjusting mode ends and returns to the original display.
HOW TO SET THE AIR FLOW DIRECTION
< WIRED REMOTE CONTROL >
NOTICE
(downwards)
(horizontal)
the position of the louver
[EXAMPLE] For Upper position 2, Lower position 6
Lower
position
Movable
range
Upper
position
When plural remote controllers are connected, louver position setting cannot be set by slave remote control.
If you press RESET button during settings, the display will return to previous display. If you press
button during settings, the mode will end and the original display will return, and the settings that have not been
completed will become invalid.
Note : If the upper limit position number and the lower limit
position number are set to the same position, the louver
is fixed at that position. And auto swing does not function.
Clean the filter frequently
See page 16
If the filter is clogged…
The cooling/heating capacity will get reduced. Moreover it leads
to waste of electricity and larger operation noise.
It may cause failure.
Dew may form and drop during cooling.
Do not block the inlet and outlet grilles of the
indoor and outdoor units.
Excessive load to the unit may cause failure.
Keep moderate room temperature
Too much cooling or heating is not good for your health. It will also
waste the electricity.
Block direct sunlight and prevent draft
Block direct sunlight with blinds and curtains during cooling. Close
the windows and doors except when ventilation is necessary.
Adjust the airflow properly
Do not expose yourself directly to the airflow for too long time. For
small animals and plants, it is harmful as well.
If you feel cold underneath your feet during heating
If the ceiling is so high that the warm airflow does not circulate
underneath your feet, it is recommended to use a circulator.
Consult your dealer for more detail.
Stop the operation and turn the power supply
off if there are any possibility of lightning
strikes during a thunderstorm.
Lightning strikes may lead to the failure of air-conditioning system.
FOR COMFORTABLE USE
The filter should be cleaned when
the “Filter cleaning” message
is displayed, and at the ends of
cooling and heating seasons.
HOW TO OPERATE VENTILATION (WHEN A VENTILATOR IS INSTALLED) < WIRED REMOTE CONTROL >
1 Press VENTI button.
is displayed, and the ventilation operation begins.
Stop
Press VENTI button again.
1
When the ventilator is set to “NO VENTI LINK”, the ventilator can be turned on and off independently regardless
of the operation of the air conditioner.
When the ventilator is set to “VENTI LINK”, the ventilator operation will be interlocked with the air conditioner
operation.
NOTICE
If no ventilator is connected, no operation can be performed by
pressing the ventilation button. (“ ” is displayed).
VENTILATION OPERATION NOT LINKED WITH UNIT’S
OPERATION
1 Press button.
If a ventilator is connected, ventilation will operate automatically.
is displayed.
Stop
Press button again.
NOTICE
No operation can be performed by pressing the ventilation button.
(“ is displayed).
VENTILATION OPERATION LINKED WITH UNIT’S OPERATION
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mitsubishi PSA012B790 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mitsubishi PSA012B790 in the language / languages: English as an attachment in your email.

The manual is 9,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Mitsubishi PSA012B790

Mitsubishi PSA012B790 User Manual - German - 24 pages

Mitsubishi PSA012B790 User Manual - Dutch - 24 pages

Mitsubishi PSA012B790 User Manual - French - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info