Maintenance
Hydrolution requires minimal maintenance after commissioning.
Hydrolution contains many components and is why monitoring
functions are integrated to help you.
If something abnormal occurs, a message appears about
malfunctions in the form of different “alarm” texts in display.
Checking the safety valves in indoor unit
Indoor unit has been equipped with a safety valve for the water
heater as well as a safety valve for the climate system by the
installer.
For HT30, a safety relief valve is supplied with tank unit and
the valve is installed to water pipe by installer.
FL2BP5
The climate system’s safety valve
<HMA100V, HMA100VM>
Comfort setting hot water / Maintenance
Extra Hot Water
In all Extra hot water” functions, the temperature of the hot
water increases temporarily. The temperature is rst increased
to an adjustable level by the compressor (menu 1.5) and then
the electric heater is energized until the water temperature
reaches the stop temperature (menu 1.4).
Temporary “Extra hot water” is activated manually, whilst time
based extra hot water is activated using the settings made in the
control computer.
When:
“A” appears above the
icon, temporary extra hot water
is active.
“B” appears above the
icon, time based extra hot water
is active.
NOTE
Extra hot water” usually means that the electric heater
is activated regardless of Allow add heat setting (menu
8.2.1) and therefore increases the electrical
consumption.
“Extra hot watercan be activated in three different
ways:
1.
Periodic time based extra hot water
Interval between extra hot water operation is selected
in menu 1.7. Menu 1.8 shows when the next extra hot
water operation is due.
The increased temperature is maintained by the
electric heater for one hour.
2.
Schedule time based extra hot water
The start and stop times for the day of the week when
the extra hot water operation is required are set in the
sub menus to menu 7.4.0.
The increased temperature is maintained by the
electric heater for the selected period.
3.
Temporary extra hot water
Extra hot water operation starts when Extra hot water
button is pressed, and it is kept for 3 hours. The
operation is cancelled when the button is pressed
again during the period.
The increased temperature is maintained by the
electric heater until the period of time has expired.
NOTE
Heat pump will not start until Extra hot water
period finishes. It may cause insufficient hot
water supply if big demand comes.
FL2
BP5
MT500
MT300<HMS140VA, HMS140V>
FL2
BP5
MT300<HMS140VA, HMS140V>
FL2
BP5
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mitsubishi HMA100VM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mitsubishi HMA100VM in the language / languages: English as an attachment in your email.

The manual is 2,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info