785733
8
Zoom out
Zoom in
Previous page
1/31
Next page
8 GB/IE/NI
Installation
Please familiarise yourself with the product prior
to installation. Carefully read the following in-
stallation instructions and safety advice. Incorrect
installation will void the warranty, particularly
with respect to consequential damages.
CAUTION! Turn off the water supply at the
mains before starting the installation. Other-
wise there is a risk of injury and / or property
damage.
Note: You will need an electric drill.
DANGER OF ELECTRIC SHOCK!
Before drilling, ensure that there are
no electrical cables where you in-
tend to drill.
CAUTION! RISK OF INJURY!
Read the operating instructions in-
cluded with your drill.
Note: Before installation, remove all packag-
ing material from the product.
Twist the pre-installed installation plates 17
counterclockwise to remove them from the wall
bracket 15 (see Fig. A).
First push the wall bracket
15
and then the hand-
hel
d shower head holder 19 and the second
wall bracket 15 over the shower bar 1 from
below (see Figures B to D).
Remove the connector 14 together with the brass
thread 13 from the diverter 9 (see Fig. E).
Attach the brass thread 13 with the connector
14 to the bottom of the shower bar 1 by tight-
ening it counterclockwise using the tool 11
(see Fig. F).
Attention: Left-hand thread!
Twist the diverter 9 clockwise onto the brass
thread 13 and when doing so make sure that
the seal 12 is correctly positioned (see Fig. G).
Adjust the spacing on the left and right between
the two wall brackets 15 and the handheld
shower head holder 19 on the shower bar 1,
and use a slot-head screwdriver (not included)
to tighten the screws on the shower bar 1 in
order to attach the wall brackets 15 (see Fig-
ures H and I).
Mark the drill holes using the holes in the instal-
lation plates 17 intended for the fixing screws
16 as a guide (approx. Ø 6 mm).
Now drill the mounting holes and then guide the
wall plugs 18 into the drilled holes (see Fig. J).
Attach both installation plates 17 using the fix-
ing screws 16 .
Hold the shower bar 1 with the installed wall
brackets 15 at the height of the installation
plates 17 . Put the covering rosettes for the wall
brackets 15 on the installation plates 17 and
turn the covering rosettes clockwise to tighten
(see Figures K and L). The diverter 9 must face
downwards when you do this.
Insert a hose seal 7 into the thread of the
connection hose 10 and attach the connection
hose 10 by twisting it clockwise onto the lower
thread of the diverter
9
(see Figures M and N).
Insert a hose seal 7 into the other end of the
connection hose 10 and screw this tightly onto
your water supply by hand.
Insert a hose seal 7 into the nut of the shower
hose 8 and attach this by twisting it clockwise
onto the side thread of the diverter 9 (see Fig-
ures O and P).
Attach a hose seal 7 to the other end of the
shower hose 8. Then connect the handheld
shower head 6 to the shower hose 8 by
tightening it by hand in a clockwise direction
(see Fig. Q).
Now remove the union nut 2 on the overhead
shower head 5 by twisting it counterclockwise
(see Fig. R).
Insert a seal 3 into the thread on the ball
joint 4.
Insert the ball joint 4 into the union nut 2
from below (see Fig. S).
Insert the seal 3 into the overhead shower
head 5 and screw the ball joint 4 together
with the union nut 2 clockwise onto the over-
head shower head 5 (see Figures T and U).
Attach the overhead shower head 5 by twist-
ing it clockwise onto the shower bar 1 (see
Fig. V).
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Miomare WU6823511-8 - IAN 360514 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Miomare WU6823511-8 - IAN 360514 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0.63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info