630056
14
Zoom out
Zoom in
Previous page
1/70
Next page
10
English
GB
WARNING! Read all safety warnings and all instruc-
tions. Failure to follow the warnings and instructions may result in
electric shock, re and/or serious injury. Save all warnings and
instructions for future reference.
SAFETY INSTRUCTIONS
This appliance can be used by children aged
from 8 years and above and persons withre-
duced physical, sensory or mental capabilities
or lack of experience and knowledge if
theyhave been given supervision or instruc-
tion concerning use of the appliance in a safe
way andunderstand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be
made by children without supervision.
Additional Safety and Working Instructions:
Wear ear protectors. Exposure to noise can cause hearing loss.
Use auxiliary handle(s), if supplied with the tool. Loss of
control can cause personal injury.
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory may
contact hidden wiring. Cutting accessory contacting a “live”
wire may make exposed metal parts of the power tool “live” and
could give the operator an electric shock.
Use protective equipment. Always wear safety glasses when
working with the machine. The use of protective clothing is re-
commended, such as dust mask, protective gloves, sturdy non-slip
footwear, helmet and ear defenders.
Do not use the dust extractor for drilling work in wood, steel or
plastic.
Do not use machines on any material containing asbestos.
Remove the battery pack before starting any work on the machine.
Cleaning and user maintenance shall not be made by children
without supervision.
SPECIFIED CONDITIONS OF USE
The dust extractor is designed for the extraction of dust in drilling
applications with hammer drills in stone and concrete.
BATTERIES
Battery packs which have not been used for some time should be
recharged before use.
Temperatures in excess of 50°C (122°F) reduce the performance of
the battery pack. Avoid extended exposure to heat or sunshine (risk
of overheating).
The contacts of chargers and battery packs must be kept clean.
For an optimum life-time, the battery packs have to be fully
charged, after use.
To obtain the longest possible battery life remove the battery pack
from the charger once it is fully charged.
For battery pack storage longer than 30 days: Store the battery
pack where the temperature is below 27°C and away from moisture
Store the battery packs in a 30% - 50% charged condition Every six
months of storage, charge the pack as normal.
Do not dispose of used battery packs in the household refuse or
by burning them. Milwaukee Distributors oer to retrieve old
batteries to protect our environment.
Do not store the battery pack together with metal objects (short
circuit risk).
Use only System C12 chargers for charging System C12 battery
packs. Do not use battery packs from other systems.
Never break open battery packs and chargers and store only in dry
rooms. Keep dry at all times.
Battery acid may leak from damaged batteries under extreme load
or extreme temperatures. In case of contact with battery acid wash
it o immediately with soap and water. In case of eye contact rinse
thoroughly for at least 10 minutes and immediately seek medical
attention.
No metal parts must be allowed to enter the battery section of the
charger (short circuit risk).
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods Legisla-
tion requirements.
Transportation of those batteries has to be done in accordance with
local, national and international provisions and regulations.
The user can transport the batteries by road without further
requirements.
Commercial transport of Lithium-Ion batteries by third parties is
subject to Dangerous Goods regulations. Transport preparation and
transport are exclusively to be carried out by appropriately trained
persons and the process has to be accompanied by corresponding
experts.
When transporting batteries:
Ensure that battery contact terminals are protected and insulated
to prevent short circuit. Ensure that battery pack is secured against
movement within packaging. Do not transport batteries that are
cracked or leak. Check with forwarding company for further advice
TECHNICAL DATA
Dust extractor
M12 DE
Production code 4405 01 02...
... 000001-
999999
Drilling capacity max. 16 mm
Drilling depth 120 mm
No-load speed 0-22000 min -1
Battery voltage 12 V
Weight according EPTA-Procedure 01/2003
(Li-lon 1,5 Ah / Li-lon 3,0 Ah)
1,6 kg/1,8 kg
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Milwaukee M12DE-201C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Milwaukee M12DE-201C in the language / languages: All languages as an attachment in your email.

The manual is 3,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info