641690
11
Zoom out
Zoom in
Previous page
1/39
Next page
20 21
950 K, 950 H, 950 S 900 K, 900 S
.......................1700 W .........................1600 W
.........................850 W ...........................800 W
..................125-250 min
-1
............................-
..................125-250 min
-1
............................-
................975-1950 min
-1
..............975-1950 min
-1
...........................20 J ............................... 20 J
......................28-50 mm .............................-
......................50-80 mm .............................-
....................45-150 mm .............................-
........................ 11,8 kg ..........................11,0 kg
.........................100 dB (A)
......................... 111 dB (A)
............................... ................................94 dB (A)
............................... ..............................102 dB (A)
............................... ..............................105 dB (A)
........................12,5 m/s
2
.............................2 m/s
2
........................... 11 m/s
2
..........................11 m/s
2
.............................2 m/s
2
............................2 m/s
2
ENGLISH
TECHNICAL DATA
Rated input ..............................................................................
Output ......................................................................................
No-load speed .........................................................................
Speed under load max. ...........................................................
Rate of percussion under load max. ........................................
Impact energy per stroke according to EPTA-Procedure 05/2009 ....
Drilling capacity in concrete .....................................................
Tunnel bit in concrete, bricks and limestone ...........................
Core cutter in concrete, bricks and limestone .........................
Weight according EPTA-Procedure 01/2003 ...........................
Noise Information 950 K, 950 H, 950 S
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K = 3 dB(A)) .......................................
Sound power level (K = 3 dB(A)) ............................................
Wear ear protectors!
Noise Information 900 K, 900 S
Typically the A-weighted sound pressure level of the
tool is .......................................................................................
Measured values determined according to 2000/14/EG at the
user’s ear.
2000/14/EC: Conformity assessment procedure according to
Annex VI. Notied Body:
VDE Testing and Certication Institute, Merianstr. 28,
63069 Offenbach, Germany
Measured sound power level ................................................
Guaranteed sound power level .............................................
Wear ear protectors!
Vibration Information
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Vibration emission value a
h
:
Hammer-drilling in concrete: ...................................................
Uncertainty K = .......................................................................
Chiselling: ...............................................................................
Uncertainty K = .......................................................................
WARNING! Read all safety warnings and all
instructions, including those given in the accompanying
brochure. Failure to follow the warnings and instructions
may result in electric shock, re and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Wear ear protectors when impact drilling. Exposure to
noise can cause hearing loss.
Use auxiliary handles supplied with the tool. Loss of
control can cause personal injury.
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory
may contact hidden wiring or its own cord. Cutting
accessory contacting a "live" wire may make exposed metal
parts of the power tool "live" and could give the operator an
electric shock.
Appliances used at many different locations including open
air should be connected via a residual current device of
30 mA or less.
Always wear goggles when using the machine. It is
recommended to wear gloves, sturdy non slipping shoes
and apron.
Sawdust and splinters must not be removed while the
machine is running.
Always disconnect the plug from the socket before carrying
out any work on the machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine.
Always lead the cable away behind you.
When working in walls ceiling, or oor, take care to avoid
electric cables and gas or waterpipes.
The dust produced when using this tool may be harmful to
health. Do not inhale the dust. Wear a suitable dust
protection mask.
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may signicantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may signicantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
ENGLISH
SPECIFIED CONDITIONS OF USE
950 K, 950 H, 950 S: The pneumatic hammer can be
universally used for hammer drilling and chiselling in stone
and concrete.
900 K, 900 S: The hammer can be used for chiselling in
stone and concrete.
Do not use this product in any other way as stated for
normal use.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is
in conformity with the following standards or standardized
documents:
EN 60745-1:2009 + A11:2010
EN 60745-2-6:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
in accordance with the regulations
2011/65/EU (RoHs)
2006/42/EC
2004/108/EC,
2000/14/EC (900 K, 900 S)
Winnenden, 2012-09-11
Rainer Kumpf
Director Product Development
Authorized to compile the technical le
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the
system voltage indicated on the rating plate. It is also
possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
MAINTENANCE
The ventilation slots of the machine must be kept clear at all
times.
Important note! If the carbon brushes are worn, in addition
to exchanging the brushes the tool should be sent to
after-sales service. This will ensure long service life and top
performance.
Use only Milwaukee accessories and Milwaukee spare
parts. Should components need to be replaced which have
not been described, please contact one of our Milwaukee
service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the Article No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: Milwaukee Electric Tool,
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before
starting the machine.
Always disconnect the plug from the socket
before carrying out any work on the
machine.
Accessory - Not included in standard
equipment, available as an accessory.
Do not dispose of electric tools together
with household waste material! In
observance of European Directive 2002/96/
EC on waste electrical and electronic
equipment and its implementation in
accordance with national law, electric tools
that have reached the end of their life must
be collected separately and returned to an
environmentally compatible recycling
facility.
Class II construction, tool in which
protection against electric shock does not
rely on basic insulation only, but in which
additional safety precautions, such as
double insulation or reinforced insulation,
are provided.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Milwaukee 950S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Milwaukee 950S in the language / languages: All languages as an attachment in your email.

The manual is 2,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info