Commissioning the dispensing pumps
Before the liquid dispensing pumps can be
used the liquid agent must be drawn up into
the system and the amount to be dispensed
set.
Dispenser calibration
The dispensers need to be calibrated to
ensure the dispenser pumps supply the
correct amount of liquid agent.
To calibrate the dispensers with the machine
switched off:
^
Press and hold in button 2.
^
Then switch the machine on with the "On"
switch.
Dispenser calibration ~ Main menu
Dispenser pump 1
Dispenser pump 2 e
A
Selection choice: Dispenser pumps 1 to 13
After selecting a dispenser pump the
following message will appear in the display:
Dispenser calibration ~ Dispenser pump 1
V: 100ml t: 0s no
0/1 S A
The amount to dispense can be set between
0 and 9999 ml in 1 ml increments.
^
Press the 0/1 multi-function button and the
dispenser hose will start to fill. Press the
0/1 button again to stop filling the hose.
^
Direct the hose of the dispenser pump
being calibrated into a suitable measuring
flask.
,
Avoid contact with the skin and eyes,
and wear suitable protective clothing.
^
Press the A "Back" button to return to the
main menu.
Dispenser calibration ~ Main menu
Dispenser pump 1
Dispenser pump 2 e
A
^
Select dispenser pump.
Dispenser calibration ~ Dispenser pump 1
V: 100ml t: 0s no
0/1 S A
^
Press button 0/1.
To stop the pump press the 0/1 button
again, or it will switch off automatically
after a period of 60 seconds.
^
Measure the amount collected in the
measuring flask.
Dispenser calibration ~ Dispenser pump 1
V: 100ml t: 30s P: 200.0 ml/min
0/1 S A
^ Enter this value in field "V:". Flow rate P in
ml/min will be calculated electronically.
^ Press the S "Save" button to save the
values measured in memory.
^
Reconnect the hose.
Cleaning and maintaining the dispensing
system
The dispensing system should be flushed
through with clean warm water every two
weeks and before any longer down-times to
prevent the risk of blockages and corrosion.
^
The suction pipes should be cleaned
through with water.
^
Place the suction pipes in a container of
hot water (40 - 50°C).
^
Then use the dispenser calibration system
to operate each pump until the dispensing
system is thoroughly flushed through.
^
After reconnecting all parts check all
connections, hoses, dispensers and seals
for leakages.
Optional modules
28 M.-Nr. 07 511 244
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Miele PW 6323 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Miele PW 6323 in the language / languages: English as an attachment in your email.

The manual is 7,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Miele PW 6323

Miele PW 6323 User Manual - German - 48 pages

Miele PW 6323 User Manual - Dutch - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info