Commissioning the dispensing pumps
Before the liquid dispensing pumps can be used the
liquid agent must be drawn up into the system and
the amount to be dispensed set.
Dispenser calibration
The dispensers need to be calibrated to ensure the
dispenser pumps supply the correct amount of liquid
agent.
To calibrate the dispensers with the machine
switched off:
^
Press and hold the rotary dial in.
^
Then switch the machine on with the "On" switch.
Dispenser calibration ~ Main menu
Dispenser pump 1
Dispenser pump 2 e
A
Selection choice: Dispenser pumps 1 to 13
After selecting a dispenser pump the following
message will appear in the display:
Dispenser calibration ~ Dispenser pump 1
V: 100ml t: 0s P: no
0/1 S A
The amount to dispense can be set between 0 and
9999 ml in 1 ml increments.
^
Press the 0/1 multi-function button and the
dispenser hose will start to fill. Press the 0/1 button
again to stop filling the hose.
^
Direct the hose of the dispenser pump being
calibrated into a suitable measuring flask.
,
Avoid contact with the skin and eyes, and
wear suitable protective clothing.
^
Press the A "Back" button to return to the main
menu.
Dispenser calibration ~ Main menu
Dispenser pump 1
Dispenser pump 2 e
A
^
Select dispenser pump.
Dispenser calibration ~ Dispenser pump 1
V: 100ml t: 0s P: no
0/1 S A
^
Press multi-function button 0/1.
To stop the pump press the 0/1 button again, or it
will switch off automatically after a period of 60
seconds.
^
Measure the amount collected in the measuring
flask.
Dispenser calibration ~ Dispenser pump 1
V: 100ml t: 30s P: 200.0 ml/min
0/1 S A
^ Enter this value in field "V:". Flow rate P in ml/min
will be calculated electronically.
^ Press the S "Save" button to save the values
measured in memory.
^ Reconnect the hose.
Cleaning and maintaining the dispensing system
The dispensing system should be flushed through
with clean warm water every two weeks and before
any longer down-times to prevent the risk of
blockages and corrosion.
^
The suction pipes should be cleaned through with
water.
^
Place the suction pipes in a container of hot water
(40 - 50°C).
^
Then use the dispenser calibration system to
operate each pump until the dispensing system is
thoroughly flushed through.
^
After reconnecting all parts check all connections,
hoses, dispensers and seals for leakages.
Optional modules
21
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Miele Professional PW 6207 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Miele Professional PW 6207 in the language / languages: English, Dutch as an attachment in your email.

The manual is 3,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info