666767
36
Zoom out
Zoom in
Previous page
1/80
Next page
Water drainage
Drainage AV DN 70 on the machine side, DN 70
socket on-site. Transient flow rate 200 l/min.
Foam compensator SK
Increased foaming can lead to foam being
discharged from the vapour vent. A drain with siphon
(commercial off-the-shelf pipe material) can be
retro-fitted to dispose of the foam.
Installation examples
Electrical connection
The electrical connection must only be carried out by
a suitably qualified electrician in accordance with
local and national safety regulations (BS 7671 in the
UK).
When installing a residual current device (RCD), this
must be a Type B RCD (suitable to detect high
frequency AC and DC earth leakage current).
The electrical components of machine PW 6xx7
comply with EN 60335-1 and EN 60335-2-7.
Open the machine cover. The connection points are
located on the carrier plate.
The machine is supplied ex-works for 3N AC 50-60
Hz. See data plate for details.
It is also available in the following versions:
3 N AC 380-415 V 50-60 Hz
3 AC 220-240 V 50-60 Hz
Connection should be made via a suitable isolator
which complies with local and national safety
regulations and which is easily accesible for
disconnecting the machine from the electricity
supply. Provision must be made on site to switch off
all poles. Switches with a minimum all-pole contact
gap greater than 3 mm are suitable for isolating the
machine. These include circuit breakers, fuses and
relays (IEC/EN 60947).
The isolator switch should be easily accessible for
servicing work.
If the machine is disconnected from the electricity
supply ensure adequate measures are taken to
ensure that it cannot be reconnected to the electricity
supply until all work has been carried out.
Please observe the wiring diagram supplied.
Equipotential bonding
Equipotential bonding must be carried out if required.
The electric heating is set ex-works to
9 kW PW 6107
15 kW PW 6137, PW 6167
18 kW PW 6207.
The heating will only be activated with a minimum
suds levels of 50 mm column of water.
The motor is protected by a winding to prevent it
overheating.
Connection should be made in accordance with the
wiring diagram and installation diagram to a suitable
isolator, with an on-off switch which is easily
accessible for servicing. The wiring and installation
diagrams are important for the correct electrical
functioning of the machine.
Installation and connection
36
36


Need help? Post your question in this forum.

Forumrules
1

Forum

miele-professional-pw-6167

Reset search

  • dear sirs
    we have a MIELE PW6167 machine , nowadays we are facing a problem .
    the amount of intake water due to the quantity of detergent loaded to the machine is not stable , there is a distinct deterioration .
    so please tell us about this problem and the suggested solution by your technical support team .
    thanks a lot in advance
    eng. yaghia Submitted on 7-10-2020 at 20:41

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Miele Professional PW 6167 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Miele Professional PW 6167 in the language / languages: English, Dutch as an attachment in your email.

The manual is 3,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.