666805
21
Zoom out
Zoom in
Previous page
1/74
Next page
Fire service
Programme Fabric type max. load capacity (kg, dry weight)
Face masks Face masks with
head straps
max. no. holders / masks
PT 8257 4 8
PT 8337 4 12
PT 8407 4 16
PT 8507 4 12
PT 8807 4 16
50°C, 45 min. drying phase, Cooling down phase.
Breathing masks may only be dried if special holders (available as an
optional accessory) are fitted in the drum.
Protective clothing Protective clothing (e.g. as used by the fire
brigade), overalls, jackets, trousers
PT 8257 approx.1-2suits
(1 jacket + 2 trousers or 2 jackets)
PT 8337 approx. 2 suits (or 3 jackets)
PT 8407 approx. 3 suits
PT 8507 approx.3-4suits
PT 8807 approx. 6 suits
PT 8257 5 - 6.6 kg
PT 8337 6.6 - 9 kg
PT 8407 8 - 10 kg
PT 8507 10 - 13 kg
PT 8807 16 - 20 kg
74°C, Dries to 0% residual moisture, Tumble phase, Cooling down
phase
For best results, dry items inside out.
Reproof protect.
clothing
For all textiles that have been treated with a
proofing agent
74°C, Dries to 0 % residual moisture, Tumble phase, Cooling down
phase
Only use proofing agents containing fluorochemical compounds which
are stated by the manufacturer as being "suitable for use on membrane
textiles".
Fire hazard. Do not dry items which have been treated with proofing
agents containing paraffin.
Professional cleaners
Programme Fabric type max. load capacity (kg,
dry weight)
WetCare sensitive For non washable garments PT 8257 approx.4-5
PT 8337 apporx.5-6.6
PT 8407 approx. 6.6 - 8
PT 8507 approx.8-10
PT 8807 approx. 16 - 21
50°C, 3 min. drying phase, Cooling down phase.
WetCare silks For non washable garments which crease easily PT 8257 approx.4-5
PT 8337 approx.5-6.6
PT 8407 approx. 6.6 - 8
PT 8507 approx.8-10
PT 8807 approx. 13 - 16
60°C, Dries to 15 % residual moisture, Cooling down phase.
WetCare intensive Washable garments PT 8257 approx.5-6.6
PT 8337 approx. 6.6 - 9
PT 8407 approx.8-11
PT 8507 approx. 10 - 13
PT 8807 approx. 16 - 21
74°C, Dries to 0 % residual moisture, Cooling down phase.
Temperatures given refer to extracted air temperature.
Programme overview
21
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Miele Professional PT 8807 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Miele Professional PT 8807 in the language / languages: English, Dutch as an attachment in your email.

The manual is 1,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info