666802
24
Zoom out
Zoom in
Previous page
1/74
Next page
Other options:
Town: Abingdon
Serial number: 12345678
Machine type: PT 8337
Load size: 13 kg
+ Button: Activated
Programme start: 11:30
Programme finished: 12:05
Total operating time:0h35min
Electrical energy: 12.5 kWh
Gas energy: 0 kWh
Steam energy: 0 kWh
Programme change: 2
(after making your selection and
pressing the rotary dial only the last 3 stops and starts will
be displayed.)
Programme fault: None (only the last 3 faults are saved.)
Area 1: Drying
Block1: Pre-drying
Process type: Residual moisture
Value: 15 %
Actual residual moisture: 15 %
Duration: 6 min
Max. exhaust temperature: 72 °C
Max. air intake temperature: 122 °C
Area1: Drying
Block2: Drying
Process type: Residual moisture
Value: 0 %
Actual residual moisture: 0 %
Duration: 6 min
Max. exhaust temperature: 78 °C
Max. air intake temperature: 138 °C
Area2: Cooling down
Block: Cooling down
Process type: Cooling down
Value: 50 %
Actual temperature: 50 °C
Duration: 3 min
Max. exhaust temperature: 52 °C
Max. air intake temperature: 95 °C
Residual moisture: -3 %
Delete data
Operating data module
Programme data
Delete data e
[ A
After selecting Delete data the following message will
appear in the display:
Operating data module~ Delete data
Module: 21.02.2009
Total data: 12.07.2009 e
[ A
The module menu option can be used to delete the
total data and programme data from the operating
data memory.
The total data option can only be used to delete the
total data from the operating data. The programme
data option can only be used to delete programme
data from the operating data.
After making your selection and pressing the rotary
dial you will be prompted to enter your password.
Password:____
ABCDEFGHIJKLMNOPQRSTUVWXYZ
0123456789
KSA
After keying in your password or inserting your
supervisor level key card in the reader the following
security prompt will appear in the display:
Delete operating data?
S A
After pressing the S button the data will be deleted!
Peak load cut-out
If the peak-load cut out function is activated the
heating will switch itself off and any programme
running will be stopped. The following message will
appear in the display:
1 Cottons extra dry
Prog. stopped. Peak load cut-out.
Programme will continue.
ü f
Once the peak load has finished, the programme will
continue automatically as before.
If the door is opened during the peak load cut-out the
programme will have to be started again.
Optional modules
24
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Miele Professional PT 8337 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Miele Professional PT 8337 in the language / languages: English, Dutch as an attachment in your email.

The manual is 1,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info