FREQUENCY BAND CHART
Digits displayed Country
EC 40CH FM 4W
EU Europe 40CH FM 4W / 40CH AM 1W
I2 Italy 34CH AM/FM 4W
IT Italy 40CH AM/FM 4W
PL Poland 40CH AM/FM 4W
D3 Germany 80CH FM 4W /40CH AM 1W
D4 Germany 80CH FM 4W /40CH AM 4W
UK England 40CH FM 4W UK frequencies + EC 40CH FM 4W
FOR EXTRA EU MARKET ONLY
PX Poland 400CH AM/FM 4W Polish frequencies
RU Russia 400CH AM/FM 4W
PC Private Channels 50CH AM/FM
TECHNICAL SPECIFICATIONS
GENERAL
Channels ...................................................................... (see the frequency band chart)
Frequency Range* .................................................................. 26.565-27.99125 MHz
Duty cycle (% on 1 hour) ......................................... TX 5% - RX 5% - Stand-by 90%
Frequency Control ....................................................................................................PLL
Operating Temperature Range ..................................................................-10°/+55° C
DC input voltage ..................................................................................12.6V DC ±10%
Size...........................................................................................................122x35x195mm
Weight ...................................................................................................................... 820 g
RECEIVER
Receiving system ..................................................... dual conversion superheterodyne
Intermediate frequency ......................................I° IF: 10.695 MHz • II° IF: 455 KHz
Sensitivity ..................................................................................≤ 1µV for 20 dB SINAD
Audio output power @10% THD ..........................................................4W @ 8 Ohm
Audio distortion ............................................................................less than 8% @ 1 KHz
Image rejection ........................................................................................................65 dB
Adjacent channel rejection ....................................................................................65 dB
Signal/Noise ratio ....................................................................................................45 dB
Current drain at stand/by.................................................................................< 250mA
TRANSMITTER
Output power ......................................................................................................4W max
Modulation ................................................................................FM: 1,8 KHz ± 0,2 KHz
..........................................................................................................................AM: ≥ 90%
Frequency response ............................................................................... 300 Hz/3 KHz
Output impedance .................................................................RF 50 Ohm unbalanced
Signal/Noise Ratio ........................................................................................ 40 dB MIN
Current drain ....................................................................................................... 1100mA
* covering all approved EU frequency bands
Specifications are subject to change without notice.
A readily accessible disconnect device shall be incorporated in the installation wiring.
The disconnect device shall disconnect both poles simultaneously.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midland M10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midland M10 in the language / languages: English, German, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 1,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info