481347
11
Zoom out
Zoom in
Previous page
1/16
Next page
10
Power supply
Input Rated Amp
(Switch/Fuse)
Power Cord Size
20A
2
2.0mm
220-240V~ 50Hz
or
220-230V~60Hz
NOTE: The supply voltage must be consistent with the rate voltage of the air conditioner.
ELECTRICAL WORK
Connect the cable to the indoor unit
1. Indoor/Outdoor connection cable should be H07RN-F type.
2. Lift the indoor unit panel up and remove the screw, then remove the window cover.
3. Connect cables according to their marks to terminals.
4. Wrap those cables not connected with terminals with insulation tapes, so
that they will not touch any electrical components.
1
0
mm
10
m
m
4
0
m
m
40
m
m
Cooling only
type.
Cooling & heating
type.
Code wire
Or
10m
m
4
0mm
Cooling & heating
type.
Terminal block of indoor unit
To outdoor unit
To outdoor unit
Cord clamp
1 2(N) 3 4
1 2(N) 3 4
Or
1 2(N) 3 4
To outdoor unit
Fig.20
Panel
Window cover
NOTE:
This indoor unit is especially designed to used as either MULTI models or MONO
models. Perform the following procedures to modify the indoor unit from MONO
model to MULTI model.(Fig.21 & 22)
1. Lift the indoor unit panel up, then remove the Electric control cover by loosen the screw
(See Fig.20).
2. You will find a Slide Switch, printed with MONO and MULTI words beside(Fig.21).
3. Rip off the white paper above the Slide Switch and move it to the MULTI position(see Fig. 22).
4. Reinstall the Electric control cover, close the panel.And the indoor unit can be used as
MULTI models.
MONO
MONO
MULTI
Rip off the
white paper
MONO
MONO
MULTI
MONO models MULTI models
Fig.21
Fig.22
NOTE: Before performing any electrical work, turn off the main power to the system.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midea Vertu Design at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midea Vertu Design in the language / languages: English as an attachment in your email.

The manual is 2,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Midea Vertu Design

Midea Vertu Design User Manual - English - 15 pages

Midea Vertu Design Installation Guide - Dutch - 4 pages

Midea Vertu Design User Manual - Dutch - 13 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info