Installation & Owner's Manual
3. INSTALLATION
The circulating air for every unit should be more than 350m
3
/h. Make sure there is enough Installation space. Refer outline dimensional
drawing(See Fig.2-3).
3.1 Water System Piping
1)
Water inlet or outlet pipes: The spec of the water inlet or outlet thread
is RC3/4” (external thread). Pipes must be heat-resistant and durable.
Installation of the pipe for PTR valve: The valve connecting thread
is RC3/4” (internal thread). After installation, it must be confirmed
that the drainpipe outlet is exposed in the air.
W ARNING
● Do not dismantle the PTR valve,
● Do not block off the drainage pipe, it will cause explosion
and injury.
EXPLOSION
CAUTION
Handle
Drainage
pipe
Piping water system as the above figure. In case of installing
where outside temperature falls below freezing point,
insulation must be provided for all hydraulic components.
The PTR valve should be checked every half year
to make sure that there is no restriction of the valve.
Please beware of hot water from the valve.
The drainage pipe should be well insulated
in order to prevent water inside pipe from
freezing in cold weather.
2)
3)
4)
5)
Installation of the One Way Valve: The One Way Valve thread is
RC3/4”. It is used to prevent water from flowing backwards.
After connection of the water system piping work, turn on the
cold water inlet valve and hot water outlet valve and bleed all air
from the tank. When water flows smoothly out from water outlet
pipe(tap water outlet), the tank is full, turn off all valves and
check pipeline to make sure there is no any leakage.
If the inlet water pressure is less than 0.15MPa, a pump should
be installed at the water inlet.
To guarantee the safety usage of tank, a reducing valve should
be installed in the water inlet pipe, if the water pressure exceeds
0.65MPa.
Condensate may be leaked from unit if drainage pipe is blocked,
or unit operates in high humidity environment, a drainage pan is
recommanded as shown as following figure:
Fig.3-1
Water Outlet
User
water Inlet
anode
Drainpipe
T ap W ater
Ball V alve
One W ay V alve
Barrel-drain
ExpansionTank for pressure relief
(recommended)
PTR valve
Upper
Condensate Outlet
Lower
Condensate Outlet
Notice:
The tempering valve is
required on the hot water
usage terminal.
Fig.3-2
50mm larger than
the dia. of unit
Max.22mm
Heat Pump
Water Heater
anode
anode
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midea RSJ-35 - 300RDN3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midea RSJ-35 - 300RDN3 in the language / languages: English as an attachment in your email.

The manual is 2,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Midea RSJ-35 - 300RDN3

Midea RSJ-35 - 300RDN3 User Manual - Dutch - 27 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info